Excel Function

InletPressureHarBrown


Description:

Calculates inlet pipe pressure for multiphase pipe flow using Hagedorn and Brown (1965) correlation, [psia]. Developed for vertical, upward flow and recommended only for near-vertical wellbores.

Excel Function Syntax:

=InletPressureHarBrown(Ql, Rho_l, Ul, Qg, SGgas, IFTgl, pipeID, pipeLength, pipeRoughness, P_out, T)

Parameters:

ParameterDescription
QlLiquid rate, [bbl/d].
Rho_lLiquid density, [lb/ft3].
UlLiquid viscosity, [cP].
QgGas rate, [mmscf/d].
SGgasGas specific gravity, [dimensionless].
IFTglLiquid-gas interfacial (surface) tension, [dynes/cm].
pipeIDPipe inner diameter, [in].
pipeLengthPipe length, [ft].
pipeRoughnessPipe relative roughness, [dimensionless].
P_outOutlet pipe pressure, [psia].
TTemperature at middle point of the pipe, [degF].

Related Theory


1 item

Related Functions


2 items

OutletPressureHarBrown

Calculates outlet pipe pressure for multiphase pipe flow using Hagedorn and Brown (1965) correlation, [psia]. Developed for vertical, upward flow and recommended only for near-vertical wellbores.

PressureGradientHarBrown

Calculates pressure gradient for multiphase pipe flow using Hagedorn and Brown (1965) correlation with Griffith modification, [psi/ft]. Developed for vertical, upward flow and recommended only for near-vertical wellbores.

Missing a formula?Suggest a New Formula
This website uses cookies to enhance your experience and analyze site usage. By clicking "Accept", you consent to the use of cookies for analytics purposes. Read our privacy policy