Description

Calculates cumulative water influx by van Everdingen-Hurst superposition of the pressure-drop steps, We(tj) = U times the sum over i up to j of dPi·WD(tDj − tD(i−1)). Spills one value per step, down a column, [bbl].

Syntax

=PO.MBE.Aq.VEH.We(U, dP, tD, [reD])

Parameters

Parameter Description
U Aquifer constant, [bbl/psi].
dP Pressure-drop step applied at each time; for Dake's method the averaged step (p(j−1) − p(j+1))/2, [psi].
tD Dimensionless time at each step (PO.MBE.Aq.VEH.tD), [dimensionless].
reD Optional. Dimensionless aquifer radius ra/rr, above 1, [dimensionless]. Omitted: an infinite aquifer.