Excel Function

BoSatStanding1947


Description:

Calculates oil formation volume factor using Standing (1947) correlation, P <= Pb, [bbl/STB].

Excel Function Syntax:

=BoSatStanding1947(SGgas, SGoilAPI, Rso, T)

Parameters:

ParameterDescription
SGgasGas specific gravity, [dimensionless].
SGoilAPIOil gravity, [API].
RsoSolution gas-oil ratio, [scf/STB].
TTemperature, [degF].

Usage Examples


Excel formula examples for BoSatStanding1947

FormulaResult
=BoSatStanding1947(0.75, 35, 500, 180)

Calculate saturated oil formation volume factor using Standing correlation

1.293
=BoSatStanding1947(0.786, 40.7, 569.54, 220)

Calculate oil formation volume factor at 2100 psia (below Pb=2620) using Standing (1947) correlation from TAMU PE324 Example A-9

1.3687

Related Theory


1 item

Related Functions


6 items

BoSatAlMarhoun1988

Calculates oil formation volume factor using Al-Marhoun (1988) correlation, P <= Pb, [bbl/STB].

BoSatDindorukChristman2001

Calculates oil formation volume factor using Dindoruk and Christman (2001) correlation, P <= Pb, [bbl/STB].

BoSatGlaso1980

Calculates oil formation volume factor using Glaso (1980) correlation, P <= Pb, [bbl/STB].

BoSatPetrosky1990

Calculates oil formation volume factor using Petrosky (1990) correlation, P <= Pb, [bbl/STB].

BoSatVasquezBeggs1980

Calculates oil formation volume factor using Vasquez and Beggs (1980) correlation, P <= Pb, [bbl/STB].

BoUSat

Calculates oil formation volume factor for undersaturated oil, P > Pb, [bbl/STB].