Residence time oil in separator

Input(s)

hwh_{w}: Height of Water Column in Separator (ft)

vo\mathrm{v}_{\mathrm{o}}: Terminal Velocity of Water ( ft/min\mathrm{ft} / \mathrm{min} )

Output(s)

tot_{o}: Oil Residence Time (min)

Formula(s)

to=(hw60vo)\mathrm{t}_{\mathrm{o}}=\left(\frac{\mathrm{h}_{\mathrm{w}}}{60 * \mathrm{v}_{\mathrm{o}}}\right)

Reference(s)

John M. Campbell, Gas Conditioning and Processing, Vol. 2, Page: 80, Campbell Petroleum Series, Oklahoma, 1992.