Residence time of water in separator

Input(s)

\(h_{o}\): Height of Oil Column in Separator (ft)

\(\mathrm{v}_{\mathrm{w}}\): Terminal Velocity of Water \((\mathrm{ft} / \mathrm{h})\)

Output(s)

\(t_{w}\): Residence Time of Water (min)

Formula(s)

\[ \mathrm{t}_{\mathrm{w}}=\left(\frac{\mathrm{h}_{\mathrm{o}}}{60 * \mathrm{v}_{\mathrm{w}}}\right) \]

Reference(s)

John M. Campbell, Gas Conditioning and Processing, Vol. 2, Page: 80, Campbell Petroleum Series, Oklahoma, 1992.