Spacer volume behind slurry required to balance the plug

Input(s)

Ca\mathrm{C}_{\mathrm{a}}: Annular Capacity (ft/bbl)(\mathrm{ft} / \mathrm{bbl})

E: Excess Volume (fraction)

Va\mathrm{V}_{\mathrm{a}}: Spacer Volume Ahead (bbl)(\mathrm{bbl})

Cp\mathrm{C}_{\mathrm{p}}: Capacity of Pipe or Tubing (bbl/ft)(\mathrm{bbl} / \mathrm{ft})

Output(s)

Vs\mathrm{V}_{\mathrm{s}}: Spacer Volume (bbl)

Formula(s)

Vs=(CaE) VaCp\mathrm{V}_{\mathrm{s}}=\left(\frac{\mathrm{C}_{\mathrm{a}}}{\mathrm{E}}\right) * \mathrm{~V}_{\mathrm{a}} * \mathrm{C}_{\mathrm{p}}

Reference(s)

Lapeyrouse, N. J., 2002, Formulas and Calculations for Drilling, Production and Workover, Second Edition, Gulf Professional Publishing, Page: 62.