Fluid volume required to spot a plug

Input(s)

\(\mathrm{L}_{\mathrm{t}}\): Length of Tubing or Pipe \((\mathrm{ft})\)

\(\mathrm{L}_{\mathrm{p}}\): Length of Plug \((\mathrm{ft})\)

\(\mathrm{C}_{\mathrm{t}}\): Tubing or Pipe Capacity \((\mathrm{bbl} / \mathrm{ft})\)

\(\mathrm{V}_{\mathrm{s}}\): Spacer Volume behind Slurry (bbl)

Output(s)

V: Fluid Volume Required (bbl)

Formula(s)

\[ \mathrm{V}=\left(\left(\mathrm{L}_{\mathrm{t}}-\mathrm{L}_{\mathrm{p}}\right) * \mathrm{C}_{\mathrm{t}}\right)-\mathrm{V}_{\mathrm{s}} \]

Reference(s)

Lapeyrouse, N. J., 2002, Formulas and Calculations for Drilling, Production and Workover, Second Edition, Gulf Professional Publishing, Page: 62.