Pump output triplex pump

Input(s)

ld: Liner Diameter (in.)

sl: Stroke Length (in.)

Output(s)

PO: Pump Output (bbl/stroke)

Formula(s)

PO=0.000243ld2slP O=0.000243 * l d^{2} * s l

Reference(s)

Formulas and Calculations for Drilling, Production and Workover, Second Edition, Lapeyrouse, Page: 7.