Duplex pump output - Using liner diameter

Input(s)

\(\mathrm{d}_{\mathrm{I}}\): Liner Diameter (in.)

\(1_{\mathrm{s}}\): Stroke Length (in.)

Output(s)

\(\mathrm{q}_{\mathrm{o}}\): Pump Output (bbl/stroke)

Formula(s)

\[ \mathrm{q}_{\mathrm{o}}=0.000324 *\left(\mathrm{~d}_{\mathrm{l}}^{2}\right) *\left(\mathrm{l}_{\mathrm{s}}\right) \]

Reference(s)

Lapeyrouse, N. J., 2002, Formulas and Calculations for Drilling, Production and Workover, Second Edition, Gulf Professional Publishing, Page: 8.