Linear annular capacity of pipe

Input(s)

Dh\mathrm{D}_{\mathrm{h}}: Inside Diameter of Casing Against the Pipe (in.)

Do\mathrm{D}_{\mathrm{o}}: Outside Diameter of Pipe (in.)

Output(s)

Co\mathrm{C}_{\mathrm{o}}: Annular Linear Capacity of Pipe (bbl/ft)(\mathrm{bbl} / \mathrm{ft})

Formula(s)

Co=0.7854(((Dh)2)((Do)2))808.5\mathrm{C}_{\mathrm{o}}=\frac{0.7854 *\left(\left(\left(\mathrm{D}_{\mathrm{h}}\right)^{2}\right)-\left(\left(\mathrm{D}_{\mathrm{o}}\right)^{2}\right)\right)}{808.5}

Reference(s)

Samuel. E Robello. 501 Solved Problems and Calculations for Drilling Operations. Sigma Quadrant. 2015. Houston, Texas, Page: 44.