Estimating heat injection rate (steam-drive)

Input(s)

\(w_{i}\): Boiler Feed Water Rate \((\mathrm{B} / \mathrm{d})\)

\(C_{w}\): Specific Heat Capacity of Water (BTU/lbm F)

\(T_{i}\): Injection Temperature \(\left({ }^{\circ} \mathrm{F}\right)\)

\(T_{a}\): Ambient Temperature \(\left({ }^{\circ} \mathrm{F}\right)\)

\(f_{s d h}\): Steam Quality (fraction)

\(L_{h c}\): Latent Heat of Condensation (BTU/lbm)

Output(s)

\(Q_{i}\): Heat Injection Rate (BTU/d)

Formula(s)

\[ \mathrm{Q}_{\mathrm{i}}=\mathrm{w}_{\mathrm{i}} * 62.4 * 5.615 *\left(\mathrm{C}_{\mathrm{w}} *\left(\mathrm{~T}_{\mathrm{i}}-\mathrm{T}_{\mathrm{a}}\right)+\mathrm{f}_{\mathrm{sdh}} * \mathrm{~L}_{\mathrm{hc}}\right) \]

Reference(s)

Pratts, M. (1986). Thermal Recovery Monograph Vol. 7. Society of Petroleum Engineers, Houston, Page: 76.