Estimating heat injection rate (steam-drive)

Input(s)

wiw_{i}: Boiler Feed Water Rate (B/d)(\mathrm{B} / \mathrm{d})

CwC_{w}: Specific Heat Capacity of Water (BTU/lbm F)

TiT_{i}: Injection Temperature (F)\left({ }^{\circ} \mathrm{F}\right)

TaT_{a}: Ambient Temperature (F)\left({ }^{\circ} \mathrm{F}\right)

fsdhf_{s d h}: Steam Quality (fraction)

LhcL_{h c}: Latent Heat of Condensation (BTU/lbm)

Output(s)

QiQ_{i}: Heat Injection Rate (BTU/d)

Formula(s)

Qi=wi62.45.615(Cw( TiTa)+fsdh Lhc)\mathrm{Q}_{\mathrm{i}}=\mathrm{w}_{\mathrm{i}} * 62.4 * 5.615 *\left(\mathrm{C}_{\mathrm{w}} *\left(\mathrm{~T}_{\mathrm{i}}-\mathrm{T}_{\mathrm{a}}\right)+\mathrm{f}_{\mathrm{sdh}} * \mathrm{~L}_{\mathrm{hc}}\right)

Reference(s)

Pratts, M. (1986). Thermal Recovery Monograph Vol. 7. Society of Petroleum Engineers, Houston, Page: 76.