Water quantity that dilutes the original brine with assumed density (two-salt systems)

Input(s)

\(V_{d}\): Volume of Diluted Brine (bbl)

\(\rho_{i}\): Density of initial, undiluted Brine \((\mathrm{lbm} / \mathrm{bbl})\)

\(\rho_{d}\): Density of Diluted Brine \((\mathrm{lbm} / \mathrm{bbl})\)

\(\rho_{8.33}\) : Density of Water diluting the Original Brine \((\mathrm{lbm} / \mathrm{bbl})\)

Output(s)

\(V_{8.33}\): Volume of Water Diluting the Original Brine (bbl)

Formula(s)

\[ V_{8.33}=\left(V_{d}\right) \frac{\left(\rho_{i}-\rho_{d}\right)}{\left(\rho_{i}-\rho_{8.33}\right)} \]

Reference(s)

Bridges, K. L. (2000). Completion and Workover Fluids (Vol. 19). Society of Petroleum Engineers, Page: 56.