Water loading in adsorption unit

Input(s)

q: Flow Rate \((\mathrm{mmscf} / \mathrm{d})\)

w: Water Content (lb/mmscf)

d: Bed Diameter \((\mathrm{ft})\)

Output(s)

\(q_{l}\): Water Loading \(\left(\mathrm{lb} / \mathrm{ft}^{2} \mathrm{~h}\right)\)

Formula(s)

\[ \mathrm{q}_{1}=\frac{0.053 * \mathrm{q} * \mathrm{w}}{\mathrm{d}^{2}} \]

Reference(s)

Campbell, J. M., (1992, Oklahoma (United States)) Gas Conditioning and Processing Volume 2, Campbell Petroleum Series, Page: 391.