Slope of pseudo-steady state flow in pressure buildup test

Input(s)

Q: Flow Rate (STB/day)

B: Formation Volume Factor (bbl/STB)

\(c_{t}\): Total Compressibility \((1 / \mathrm{psi})\)

A: Drainage Area \(\left(\mathrm{ft}^{2}\right)\)

\(\emptyset\): Porosity (fraction)

\(\mathrm{h}\): Thickness (ft)

Output(s)

\(m_{p s s}\): Slope \((\mathrm{psi} / \mathrm{h})\)

Formula(s)

\[ m_{p s s}=\frac{0.23396 * Q * B}{c_{t} * A * h * \phi} \]

Reference(s)

Ahmed, T., McKinney, P.D. 2005. Advanced Reservoir Engineering, Gulf Publishing of Elsevier, Chapter: 1, Page: 33 .