Shape factor expressed as skin factor for vertical wells

Input(s)

\(C_{A}\): Shape Factor (dimensionless)

Output(s)

\(s_{C A}\): Shape Related Skin Factor (dimensionless)

Formula(s)

\[ s_{C A}=\ln \left(\left(\frac{31.62}{C_{A}}\right)^{0.5}\right) \]

Reference(s)

Joshi, S. D. 1991, Horizontal Well Technology. Tulsa, Oklahoma: PennWell Publishing Company. Chapter: 7, Page: 208 .