Safety relief valves sizing in vapor services

Input(s)

C: Specific Heat Ratio (dimensionless)

Ko\mathrm{K}_{\mathrm{o}}: Valve Discharge Coefficient (dimensionless)

A: Effective Discharge Area (in. 2{ }^{2} )

B: Conversion constant (dimensionless)

P: Upstream Relieving Pressure (psi)

M: Gas Molecular Weight (dimensionless)

Z: Compressibility Factor (dimensionless)

T\mathrm{T}: Inlet Temperature (R)

Output(s)

w: Weight Flow Through Valve (lb/h)

Formula(s)

w=(B)C Ko AP(MZ T)0.5\mathrm{w}=(\mathrm{B}) * \mathrm{C} * \mathrm{~K}_{\mathrm{o}} * \mathrm{~A} * \mathrm{P} *\left(\frac{\mathrm{M}}{\mathrm{Z} * \mathrm{~T}}\right)^{0.5}

Reference(s)

John M. Campbell, Gas Conditioning and Processing, Campbell Petroleum Series, Oklahoma, 1992, Vol. 1, Page: 296.