Input(s)

\(V_{k}\): Calibration Volume of Specific Gravity bottle (Pycnometer) \(\left(\mathrm{mL}\right.\) or \(\left.\mathrm{cm}^{3}\right)\)

\(T_{t}\): Test Temperature \(\left({ }^{\circ} \mathrm{C}\right)\)

\(T_{k}\): Calibration Temperature \(\left({ }^{\circ} \mathrm{C}\right)\)

\(\Omega\): Material Constant (for Ordinary Glass \(=0.276 \cdot 10^{-4} /{ }^{\circ} \mathrm{C}\) )

\(\Omega\): Material Constant (for Pyrex Glass \(=0.156 \cdot 10^{-4} /{ }^{\circ} \mathrm{C}\) )

Output(s)

\(V_{g}\): Real Volume of Specific Gravity bottle (Pycnometer) \(\left(\mathrm{mL}\right.\) or \(\left.\mathrm{cm}^{3}\right)\)

Formula(s)

\[ \mathrm{V}_{\mathrm{g}}=\mathrm{V}_{\mathrm{k}}\left[1+\Omega\left(\mathrm{T}_{\mathrm{g}}-\mathrm{T}_{\mathrm{k}}\right)\right] \]

Reference(s)

Mihcakan, I.M., Alkan, K.H., Ugur, Z., Petroleum and Natural Gas Laboratory, Course Notes, I-Fluid Properties, ITU, Petroleum and Natural Gas Engineering, Istanbul, Turkey, 2001. Page 1-4.