Modified Cole plot

Input(s)

G: Gas in Place (SCF)(\mathrm{SCF})

We\mathrm{W}_{\mathrm{e}}: Cumulative Water Influx (bbl)(\mathrm{bbl})

Et\mathrm{E}_{\mathrm{t}}: Total Expansion Term (bbl/SCF)(\mathrm{bbl} / \mathrm{SCF})

Output(s)

FEt\frac{\mathrm{F}}{\mathrm{E}_{\mathrm{t}}}: Fluid Withdrawal (bbl)(\mathrm{bbl})

Formula(s)

FEt=G+(WeEt)\frac{\mathrm{F}}{\mathrm{E}_{\mathrm{t}}}=\mathrm{G}+\left(\frac{\mathrm{W}_{\mathrm{e}}}{\mathrm{E}_{\mathrm{t}}}\right)

Reference(s)

Ahmed, T., McKinney P.D. 2005. Advanced Reservoir Engineering, Gulf Publishing of Elsevier, Chapter: 3, Page: 212 .