Modified Clapeyron criteria

Input(s)

C: Component Constant for Hydrocarbon Levels to Pressure (K)

Output(s)

T\mathrm{T}: Hydrate Forming Temperature (R)

Formula(s)

T=3.89(C0.5)\mathrm{T}=3.89 *\left(\mathrm{C}^{0.5}\right)

Reference(s)

John M. Campbell, Gas Conditioning and Processing, Campbell Petroleum Series, Oklahoma, 1992, Vol. 1, Page: 178