Kick analysis - Shut-in drill pipe pressure

Input(s)

\(P_{f p}\): Formation Pressure (psi)

mw: Mud weight (ppg)

\(\mathrm{h}\): height \((\mathrm{ft})\)

Output(s)

SIDPP: Shut in Drill Pipe Pressure (psi)

Formula(s)

\[ S I D P P=P_{f p}-(m w * 0.052 * h) \]

Reference(s)

Formulas and Calculations for Drilling, Production and Workover, Second Edition, Lapeyrouse, Page: 131.