Inflow performance relationship (IPR) for horizontal wells in solution gas-drive reservoirs (Vogel)

Input(s)

\(q_{\text {omax }}\): Maximum Flow Rate for \(100 \%\) Drawdown (STB/day)

\(P_{w f}\): Flowing Bottomhole Pressure (psi)

\(P\): Shut in Pressure or Average Reservoir Pressure (psi)

Output(s)

\(q_{o}\): Oil Flow Rate (STB/day)

Formula(s)

\[ q_{o}=q_{\text {omax }} *\left(1-0.2 *\left(\frac{P_{w f}}{P}\right)-0.8 *\left(\frac{P_{w f}}{P}\right)^{2}\right) \]

Reference(s)

Joshi, S. D. 1991, Horizontal Well Technology. Tulsa, Oklahoma: PennWell Publishing Company. Chapter: 7 , Page: 240.