Fraction of heat injected in latent form - Myhill and Stegemeier
Input(s)
\(\mathrm{h}\): Height (ft)
\(h_{t}\): Cumulative Height \((\mathrm{ft})\)
k: Permeability \((\mathrm{mD})\)
\(k_{t}\): Cumulative Permeability \((\mathrm{mD})\)
Output(s)
FMO: FMO (dimensionless)
Formula(s)
\[
F M O=\left(\frac{1}{h_{t}}\right) *\left(h+\frac{k_{t} * h_{t}-k * h}{k}\right)
\]
Reference(s)
Ehrlich, R., 2016.PT E 531 Enhanced Oil Recovery. University of Southern California Lecture Notes.