Equivalent water saturation in burned zone in-situ combustion by Nelson

Input(s)

x\mathrm{x}: Equivalent H/C\mathrm{H} / \mathrm{C} Molar Ratio (ratio)

\emptyset: Volume of Air Required to Burn through a Unit Volume of Reservoir (Mscf/ ft3\mathrm{ft}^{3} )

ara_{r}: Volume Required to Burn through Reservoir (ft3)\left(\mathrm{ft}^{3}\right)

m: Ratio of Carbon Monoxide to Carbon Emissions (fraction)

Output(s)

SwFS_{w F}: Water Saturation Resulting from Combustion (fraction)

Formula(s)

SwF=0.319xar(42 m+x)\mathrm{S}_{\mathrm{wF}}=\frac{0.319 * \mathrm{x} * \mathrm{a}_{\mathrm{r}}}{\emptyset *(4-2 * \mathrm{~m}+\mathrm{x})}

Reference(s)

Prats, M. 1986. Thermal Recovery. Society of Petroleum Engineers, New York, Chapter: 8, Page: 92.