Dimensionless time for interference testing in homogeneous reservoirs - Earlougher

Input(s)

k: Permeability (mD)

\(\emptyset\): Porosity (fraction)

\(\mathrm{t}\): Time \((\mathrm{h})\)

\(\mathrm{k}\): Overall Production \((\mathrm{mD})\)

\(\mu\): Viscosity \((\mathrm{cP})\)

\(c_{t}\): Total Compressibility \((1 / p s i)\)

\(\mathrm{r}_{\mathrm{w}}\): Wellbore Radius (ft)

Output(s)

\(t_{D}\): Dimensionless Time (dimensionless)

Formula(s)

\[ \mathrm{t}_{\mathrm{D}}=\frac{0.0002637 * \mathrm{k} * \mathrm{t}}{\emptyset * \mathrm{c}_{\mathrm{t}} * \mu *\left(\mathrm{r}_{\mathrm{w}}^{2}\right)} \]

Reference(s)

Ahmed, T., McKinney, P.D. 2005. Advanced Reservoir Engineering, Gulf Publishing of Elsevier, Chapter: 1, Page: 117.

An unhandled error has occurred. Reload 🗙