Correction factor for stagnant film according to the penetration model

Input(s)

\(\emptyset\): Rate Factor \((\mathrm{rad})\)

Output(s)

\(\theta\): Correction Factor (dimensionless)

Formula(s)

\[ \theta=\frac{\exp \left(\frac{-(\varnothing)^{2}}{3.142}\right)}{1+\operatorname{erf}\left(\frac{\varnothing}{(3.142)^{0.5}}\right)} \]

Reference(s)

Bird, R.B., Stewart, W.E. and Lightfoot, E.N. (2002). Transport Phenomena (Second Ed.). John Wiley & Sons, Chapter: 22, Page: 707.