Additive crystalline salt amount to increase the density - Method I (single-salt systems)

Input(s)

ViV_{i}: Volume of Initial Brine Formulation (bbl)

ρi\rho_{i} : Density of Fluid (g/cm3)\left(\mathrm{g} / \mathrm{cm}^{3}\right)

CsfC_{s f}: Concentration of Salt in Final Formulation (%)

CsiC_{s i}: Concentration of Salt in Initial Formulation (%)

PsP_{s}: Purity of Salt to be added (%)

Output(s)

[^1]

Formula(s)

ms=Vi(42gal/bbl)(ρi)(CsfCsi)PsmCsfm_{s}=\frac{V_{i}(42 \mathrm{gal} / \mathrm{bbl})\left(\rho_{i}\right)\left(C_{s f}-C_{s i}\right)}{P_{s}-m C_{s f}}

Reference(s)

Bridges, K. L. (2000). Completion and Workover Fluids (Vol. 19). Society of Petroleum Engineers, Page: 54.