id: po.wb.sf.facility-sizing
title: Surface Facility Sizing
summary: "How big a separator, how much compression and which wellhead choke one well stream needs, from its gas, oil and water rates and pressures."
category: Production
requires:
  - po-addin
  - excel-365
tags:
  - separator
  - vessel-sizing
  - souders-brown
  - retention-time
  - compressor
  - compression-power
  - choke
  - wellhead-choke
  - surface-facilities
---

## Description

What does the facility for one well stream need: how big a separator, how many compressor stages and how much power, and which choke bean? You enter the stream's gas, oil and water rates, the gas composition, the separator, compressor and choke pressures and the design basis. You read off the recommended separator size and the rating of an existing vessel, the compressor stages, discharge temperature and brake power against the driver, and the bean with the rate it passes and whether the flow is critical.

**How to use it:** Put the stream on each sheet; the defaults are the same rates as the pipeline design workbook's route, so the facility is sized for the same well. On the Separator sheet enter the operating pressure and temperature, the orientation and phases, the retention times from bottle tests, the K factor from the mist extractor's rating, the slenderness limits and the existing vessel. On the Compression sheet enter the suction and discharge pressures, the machine basis and efficiencies, the largest ratio per stage, the temperature limit and the driver rating. On the Choke sheet enter the wellhead and flowline pressures and the well stream. Each sheet states its own checks; the Summary lists them all and gives one verdict.

**Method:** The separator is sized by Souders-Brown for the gas and by the retention times for the liquid: the allowable gas velocity is K over the square root of the density ratio, with the gas density from a DAK Z-factor on Standing pseudo-criticals corrected for CO2 and H2S by Wichert-Aziz. The recommended vessel is the smallest standard diameter that carries the gas within the allowable velocity and holds the oil and water for their times within the slenderness limits (seam-to-seam length over diameter); the existing vessel is rated against the same duty. The compression takes the fewest stages within a largest ratio per stage, the discharge temperature of each stage cooled back to the suction temperature between stages, and the head and gas power of each stage at its own average Z, with k from the gas gravity by Moshfeghian unless a value is typed; the brake power is the gas power over the mechanical efficiency. The choke is sized by Gilbert's critical-flow correlation for the liquid rate and gas-liquid ratio, rounded up to the next 1/64 in, and checked against the critical pressure ratio from k, with Sachdeva's mechanistic model beside it as a second opinion.

**Example:** The default stream is the flow-assurance family's reference flowline: 20 MMscf/d of a 0.7 gravity gas with 3 % CO2 and 500 ppm H2S, 1,000 STB/d of the 40.7 API reference oil and 500 bbl/d of water, at 250 psia and 80 F in the separator, compressed from 250 psia to 1,000 psia, and choked from 2,000 psia into the flowline at 1,000 psia. The separator needs 35.79 in for the gas, so the recommended vessel is 42 in by 16.21 ft seam to seam, a slenderness of 4.63. The compressor takes two stages at a ratio of 2, each discharging at 184 F, and needs 1,686 brake hp, 84 % of the 2,000 hp driver. The choke is 18/64 in, passing 1,551 bbl/d at a pressure ratio of 0.500, at or below the critical 0.551, so the flow is critical and Gilbert's correlation applies.

## Validity

The Souders-Brown K factor has to come from the mist extractor's rating and the retention times from bottle tests: the sheet checks them against API 12J's ranges (1 to 3 min two-phase, 3 to 30 min three-phase) but cannot set them. The compression is steady and ignores real-gas deviation beyond the stages' own Z; a real machine needs its vendor's polytropic data. Gilbert's correlation applies only where the flow is critical, which the critical-flow check states.

## References

- Souders, M. and Brown, G.G. (1934). Design of Fractionating Columns I. Entrainment and Capacity. *Ind. Eng. Chem.* 26(1), 98-103.
- Gilbert, W.E. (1954). Flowing and Gas-Lift Well Performance. *API Drilling and Production Practice*, 126-157 (the choke's critical-flow correlation).
- Sachdeva, R., Schmidt, Z., Brill, J.P. and Blais, R.M. (1986). Two-Phase Flow Through Chokes. SPE-15657-MS.
- API Spec 12J, *Specification for Oil and Gas Separators*.
- Arnold, K. and Stewart, M. (2008). *Surface Production Operations, Vol. 1: Design of Oil Handling Systems and Facilities*, 3rd ed. Gulf Professional Publishing.
- GPSA (2012). *Engineering Data Book*, 13th ed., section 17.

## Inputs

| Input | Unit | Default | Name |
|---|---|---|---|
| Gas rate (Separator) | MMscf/d | 20 | `VSL_Qg` |
| Oil rate (Separator) | STB/d | 1,000 | `VSL_Qo` |
| Water rate (Separator) | bbl/d | 500 | `VSL_Qw` |
| Separator operating pressure, absolute | psia | 250 | `VSL_P` |
| Separator operating temperature, after the inlet heater | F | 80 | `VSL_T` |
| Gas specific gravity (air = 1) | — | 0.7 | `VSL_SG` |
| CO2 mole fraction | % | 3 | `VSL_CO2` |
| H2S in the gas | ppm | 500 | `VSL_H2S` |
| Liquid specific gravity, oil and water blended | — | 0.89 | `VSL_SGL` |
| Orientation (1 horizontal, 2 vertical) | — | 1 | `VSL_Orient` |
| Phases separated (2 gas-liquid, 3 gas-oil-water) | — | 3 | `VSL_Phases` |
| Retention time of the oil | min | 10 | `VSL_TrO` |
| Retention time of the water | min | 10 | `VSL_TrW` |
| Souders-Brown K factor for the vessel and mist extractor | ft/s | 0.5 | `VSL_K` |
| Smallest slenderness, seam-to-seam length over diameter | — | 3 | `VSL_SRmin` |
| Largest slenderness | — | 5 | `VSL_SRmax` |
| Existing vessel internal diameter | in | 48 | `VSL_Dv` |
| Existing vessel seam-to-seam length | ft | 15 | `VSL_Lv` |
| Gas rate (Compression) | MMscf/d | 20 | `CPR_Qg` |
| Suction pressure of the first stage, absolute | psia | 250 | `CPR_Ps` |
| Final discharge pressure, absolute | psia | 1,000 | `CPR_Pd` |
| Suction temperature of every stage | F | 80 | `CPR_Ts` |
| Gas specific gravity (air = 1) | — | 0.7 | `CPR_SG` |
| CO2 mole fraction, H2S in the gas | %, ppm | 3, 500 | `CPR_CO2`, `CPR_H2S` |
| Basis (1 adiabatic, reciprocating; 2 polytropic, centrifugal) | — | 1 | `CPR_Mode` |
| Isentropic (1) or polytropic (2) efficiency | — | 0.8 | `CPR_Eff` |
| Largest pressure ratio per stage | — | 3.5 | `CPR_Rmax` |
| Ratio of specific heats (0 takes the gravity by Moshfeghian) | — | 0 | `CPR_kTyped` |
| Mechanical efficiency, gas power to brake power | — | 0.95 | `CPR_Mech` |
| Highest discharge temperature allowed | F | 300 | `CPR_Tmax` |
| Driver rated power | hp | 2,000 | `CPR_Driver` |
| Upstream (flowing wellhead) pressure, absolute | psia | 2,000 | `CHQ_Pup` |
| Downstream (flowline) pressure, absolute | psia | 1,000 | `CHQ_Pdn` |
| Upstream temperature | F | 150 | `CHQ_T` |
| Oil rate (Choke) | STB/d | 1,000 | `CHQ_Qo` |
| Water rate (Choke) | bbl/d | 500 | `CHQ_Qw` |
| Producing gas-oil ratio | scf/STB | 768 | `CHQ_GOR` |
| Stock-tank oil gravity | °API | 40.7 | `CHQ_API` |
| Separator gas specific gravity | — | 0.855 | `CHQ_SGg` |
| Gas specific heat ratio, Cp over Cv | — | 1.27 | `CHQ_k` |

## Sheets

- `Guide` — what the workbook decides (how big the separator, what the compression costs, which bean) and the default stream.
- `Separator` — the stream at the facility, gas and liquid densities, the Souders-Brown allowable velocity and the diameter the gas needs, the liquid held for the retention times, the standard vessels from 24 to 120 in with their lengths and slenderness, the recommended vessel and what sets its diameter, the existing vessel's rating, and the slenderness, retention-time and existing-vessel checks.
- `Compression` — the gas and the duty, k, the overall and per-stage ratios, the stages cooled back to the suction temperature between them, each stage's discharge temperature, Z and gas power, the power the interstage cooling saves, the brake power and the checks.
- `Choke` — the wellhead and flowline pressures and the well stream, the liquid rate, water cut, gas-liquid ratio and pressure ratio against the critical ratio, the Gilbert bean and the rate through it, and the Sachdeva size beside it.
- `Summary` — the separator, compression and choke headlines and every check under one verdict.
- `Test Cases` — the worked example and other cases, with expected and computed results.

## Functions used

`PO.SF.Sep.SoudersBrown`, `PO.SF.Sep.LiquidRetention`, `PO.SF.Comp.Stages`, `PO.SF.Comp.Tdisch`, `PO.SF.Comp.Power`, `PO.SF.Comp.k`, `PO.SF.CH.Gas.Rcrit`, `PO.SF.CH.Gilbert.Size`, `PO.SF.CH.Gilbert.Rate`, `PO.SF.CH.Sachdeva.Size`, `PO.PVT.Ppc.ByStanding.Sour`, `PO.PVT.Tpc.ByStanding.Sour`, `PO.PVT.Z.ByDAK`, `PO.PVT.Rho.Gas.ByDefinition`, `PO.PVT.Rho.Wat.Stn`, `PO.PVT.Bg.ByDefinition`.