id: po.wb.ipr.gas-well-deliverability
title: Gas Well Deliverability
summary: "How much gas one well delivers and when it will load up, from a four-point test fit through the tubing to critical rates along a decline."
category: Production
requires:
  - po-addin
  - excel-365
tags:
  - IPR
  - VFP
  - gas
  - deliverability
  - liquid-loading
---

## Description

How much gas can this well deliver, and when will it start to load up with liquid? You enter the reservoir and completion, four stabilized flow-after-flow test points, the tubing and wellhead, the water yield, an independent gauge test and a synthetic decline. You read off the backpressure and laminar-inertial-turbulent fits with their AOF, the tubing's match to the gauge, and the Turner, Coleman and Li critical rates along the tubing and against the decline. Pressures psia; inflow rates Mscf/d, tubing and loading rates MMscf/d.

**How to use it:** The well and its test are synthetic; replace the example with measured data. Enter the reservoir, completion and the four stabilized test points on the Inflow sheet; the Fetkovich sheet reads them and needs no input. Enter the tubing, wellhead, water properties, the current rate and the gauge test on the Tubing sheet, and check the correlations against the gauge. Replace the synthetic decline on the Loading sheet with a history fit, then read the lead time to lift and every check on the Summary.

**Method:** Fit the four stabilized test points using pressure-squared backpressure and laminar-inertial-turbulent equations, and compare the Fetkovich equation at the same pressures. Calculate a two-pass single-phase gas tubing pressure and compare it with multiphase correlations at the gauge rate, then compare Turner, Coleman and Li critical rates along the tubing against a synthetic Arps decline.

**Example:** The gas reference well is at 3000 psia and 160 F, with gas gravity 0.7, 8 mD, 40 ft pay and skin 2. Its synthetic stabilized test is (2700, 3090), (2400, 5400), (2000, 8210), (1500, 10350) in psia and Mscf/d. The tubing is 7500 ft TVD, 2.441 in ID and 1200 psia at the wellhead.

## Validity

This is a stabilized flow-after-flow test, not an isochronal analysis. An isochronal test needs transient coefficients and an extended stabilized point. The Fetkovich equation normally describes oil: its reservoir and test data are overridden with the gas well's points and Mscf/d rates here, and its oil equations are numerical checks, not validation of a gas physical model. Its zero-pressure AOF is not the gas AOF at the 14.7 psia base; compare the rates at the same flowing pressure. The tubing chart is a comparison, not an operating-point solve. The loading decline is synthetic, holds wellhead pressure fixed and must be replaced by a history fit. Turner, Coleman and Li are empirical estimates, not proof of unloading.

## References

- Fetkovich, M.J. (1973), The Isochronal Testing of Oil Wells, SPE 4529.
- Turner, R.G., Hubbard, M.G. and Dukler, A.E. (1969), Analysis and Prediction of Minimum Flow Rate for the Continuous Removal of Liquids from Gas Wells, JPT.
- Coleman, S.B. et al. (1991), A New Look at Predicting Gas-Well Load-Up, JPT.

## Inputs

| Input | Unit | Default | Name |
|---|---|---|---|
| Reservoir pressure | psia | 3000 | `GDI_Pr` |
| Reservoir temperature | F | 160 | `GDI_T` |
| Gas specific gravity | — | 0.7 | `GDI_SG` |
| Permeability | mD | 8 | `GDI_k` |
| Net pay | ft | 40 | `GDI_h` |
| Perforated interval | ft | 20 | `GDI_hp` |
| Drainage radius | ft | 2980 | `GDI_re` |
| Wellbore radius | ft | 0.354 | `GDI_rw` |
| Skin | — | 2 | `GDI_s` |
| AOF base pressure | psia | 14.7 | `GDI_Pbase` |
| Operating flowing pressure | psia | 1000 | `GDI_PwfOp` |
| Minimum log-log fit R squared | — | 0.98 | `GDI_R2Min` |
| AOF comparison tolerance | fraction | 0.1 | `GDI_AofTol` |
| Four stabilized points: Pwf and rate | psia, Mscf/d | see the example | `GDI_Pwf`, `GDI_Q` |
| Tubing depth | ft | 7500 | `GDT_TVD` |
| Tubing inner diameter | in | 2.441 | `GDT_ID` |
| Relative roughness | — | 0.0006 | `GDT_Rough` |
| Wellhead pressure | psia | 1200 | `GDT_Pwh` |
| Wellhead temperature | F | 100 | `GDT_Twh` |
| Water-gas ratio | bbl/MMscf | 5 | `GDT_WGR` |
| Water density | lb/ft3 | 67 | `GDT_RhoL` |
| Water viscosity | cp | 0.5 | `GDT_UL` |
| Water surface tension | dyne/cm | 60 | `GDT_IFT` |
| Current gas rate | MMscf/d | 8.21 | `GDT_Qg` |
| Gauge test gas rate | MMscf/d | 8.21 | `GDT_Qtest` |
| Gauge pressure at the test rate | psia | 2000 | `GDT_Pmeas` |
| Turner adjustment | — | 1.2 | `GDT_TurnerF` |
| Gauge match tolerance | fraction | 0.05 | `GDT_MatchTol` |
| Synthetic nominal decline per year | 1/yr | 0.35 | `GDL_Di` |
| Synthetic Arps exponent | — | 0.5 | `GDL_b` |
| Lift lead time | years | 2 | `GDL_Lead` |

## Sheets

- `Guide` — how to use the workbook, the test and its units, why the Fetkovich comparison is there, and the limitations.
- `Inflow` — the reservoir and completion, the four stabilized points, input validation and the calculation pressure, and the gas, rock and test fits by the backpressure and laminar-inertial-turbulent equations.
- `Fetkovich` — the Fetkovich equation fitted to the same gas test, read only from Inflow, with its fitted curve to the gas base pressure, charted against the test.
- `Tubing` — single-phase gas in two passes, the independent gauge test, a correlation comparison at the gauge rate, and the inflow and tubing curves charted together without an operating-point solve.
- `Loading` — the gas at the wellhead and the Turner, Coleman and Li critical rates, the profile at the wellhead Turner rate by depth, and the synthetic decline against the critical rates, charted.
- `Summary` — the inflow and matched equation, the tubing and loading results, and every check under one verdict.
- `Test Cases` — the worked example and other cases, with expected and computed results.

Four charts: the gas test and Fetkovich equation; tubing and inflow; critical rate by depth; decline against critical rates.

## Functions used

`PO.PVT.PseudoP`, `PO.IPR.GW.Backpressure.Fit`, `PO.IPR.GW.LIT.Fit`, `PO.IPR.GW.PSS.Rate`, `PO.IPR.GW.PSS.Rate.NonDarcy`, `PO.IPR.GW.D`, `PO.IPR.VW.PSS.Rate.ByFetkovich`, `PO.IPR.VW.PSS.AOF.ByFetkovich`, `PO.VFP.Gas.Pin`, `PO.VFP.Gas.Pout`, `PO.VFP.Gas.Re`, `PO.VFP.Gray.Pin`, `PO.VFP.BeggsBrill.Pin`, `PO.VFP.DunsRos.Pin`, `PO.VFP.Corr.Match`, `PO.PE.Loading.TurnerRate`, `PO.PE.Loading.LiRate`, `PO.DCA.Arps.Time`, `PO.DCA.Arps.Rate` and `PO.DCA.Arps.Prod`.