## Description

Will a well-to-facility system hydrate, scale, corrode or erode, and how bad is each threat? You enter one system: the stream, the line from the wellhead to the arrival, the formation and injection waters, the inhibitors, the design life and what each threat costs if it happens. You read off the hydrate margin and the methanol dose that clears it, the worst scale saturation index, the CO2 corrosion rate and wall loss, the erosional velocity ratio, and a risk register that rates each threat and gives the system one verdict.

**How to use it:** Put the system on the System sheet: the metered rates, the gas and water analyses, the line's own as-built length and bore, the pressure and temperature profile from a flowline model, the seabed temperature, the inhibitor concentration and the design life, and the consequence of each threat. Check the line's path against the hydrate curve on Hydrates and the saturation indices over the mixing table on Scale. Read each threat's rating on Risk and the verdict on the Summary.

**Method:** Each threat is screened on the system's own data, not taken from the threat sheets one at a time.

*Hydrates.* The hydrate point is the Katz gas-gravity curve at Towler and Mokhatab's fit, at the wellhead pressure, at the arrival pressure and at the shut-in settle-out pressure. The line's pressure-temperature path is a straight pressure line with exponential cooling toward the seabed over 21 stations, and the hydrate curve is drawn against it. The methanol's depression is Hammerschmidt inside its 20 wt % range and Nielsen-Bucklin above it, and the least margin on the system is the smaller of the flowing margin and the shut-in margin. The dose is the methanol the margin needs, by Hammerschmidt or Nielsen-Bucklin, the concentration at the coldest point, the rate into the water, the rate the gas carries off and the total, with the MEG equivalent.

*Scale.* The saturation indices are Oddo and Tomson's for calcite, barite and celestite, of the formation water at the reservoir and at the separator, and of the water mixed with the injection water at the design fraction. The mixing table sweeps the injection water's share from none to all in ten steps, and the worst index over that table is the screen. The continuous inhibitor's dose comes from the test's minimum concentration at the water rate.

*Corrosion.* The rate is de Waard-Milliams' unprotected rate of bare carbon steel at the CO2 partial pressure, its NACE SP0775 severity, the inhibited rate at the inhibitor's efficiency, the wall lost over the design life both ways, and the efficiency the allowance needs.

*Erosion.* The limit is API RP 14E's erosional velocity, C over the square root of the no-slip mixture density, against the mixture velocity in the line's bore; the ratio carries the risk class.

*The risk register.* Each threat's likelihood comes from its own computed margin: the least hydrate margin, the worst saturation index, the wall lost over the allowance, and the velocity ratio. The consequence is what that threat costs if it happens, a number the reader sets on System. The two multiply into a score, and the score is rated Low, Medium, High or Critical. The register's highest score is the system's risk.

**Example:** The default system is a 6-in subsea tieback: a wellhead at 1,000 psia and 150 F, a flowline that arrives at the facility at 45 F, and the produced water that comes with it. The hydrate temperature at the arrival is 60.38 F against the 45 F arrival, so the bare line is 15.38 F inside the hydrate curve. At 30 wt % methanol the depression is 27.98 F and the least margin on the system is 3.38 F, shut in, above the 3 F wanted; the margin needs 29.68 wt % methanol, so 30 wt % clears it.

The scale screen reads a worst index of 2.61 for barite, so the water can scale and wants the continuous inhibitor at its test's 15 ppm. The corrosion screen is the one that fails: at 30 psia of CO2 the bare steel loses 9.18 mm a year, 183.60 mm over the 20 year life, and even at 85 % inhibition 27.54 mm, over the 3 mm allowance, so duplex is the first-pass material (the line is in sour region 2, where 13Cr is not allowed) and the allowance would want 98.4 % inhibitor efficiency. The erosion screen passes at 0.55 of the erosional velocity. The register's highest score is 15, High, on the corrosion.

The system holds on hydrates and erosion, warns on scale and fails the corrosion allowance: the line needs a corrosion-resistant alloy, not carbon steel.

## Validity

A screen, as each threat's own sheet states in full. The hydrate fit is for a sweet natural gas with free water, gravity 0.5 to 1.8, and it carries no correction for N2, CO2, H2S or salt; the path is a model, not a measurement, so a flowline model's stations should replace it. The scale indices are screening values: the Oddo and Tomson constants were transcribed from a 2024 reprint and have not yet been checked against the 1994 paper, SPE-21710-PA, so the index is labelled as a screening value on the sheet and the register rates scale on it. The corrosion rate is the unprotected de Waard-Milliams rate, an upper bound above 140 F where iron carbonate scale can form. API RP 14E's limit is conservative and does not model sand. The likelihood bands and the consequence weights are this workbook's own choices and sit in the Calculation Constants.

The sour-service region is read from the lines of ISO 15156-2 Figure 1. At the default 0.5 psia of H2S and pH 5.0 the point is region 2, 0.04 pH units below the region 1 line, so it is marginal: a better in-situ pH can move it to region 1, and the material to 13Cr. The region steers the material, but no check is built on it.

The add-in has no functions for the wax appearance temperature, so wax is not screened; for a hydrate curve from van der Waals-Platteeuw with brine and inhibitor, so the Katz-gravity curve stands; or for the NORSOK M-506 corrosion rate that models the scale, the pH and the wall shear stress, so the de Waard-Milliams rate stands.

Named alternatives: a Pitzer-based aqueous model (PHREEQC, ScaleSoftPitzer, OLI) for the scale indices; a flowline thermal model (OLGA, PIPESIM) for the path; a sand erosion rate (DNV RP O501) for a line carrying solids; and a squeeze design on the inhibitor's adsorption isotherm instead of continuous injection.

## References

- Katz, D.L. (1945). Prediction of Conditions for Hydrate Formation in Natural Gases. *Trans. AIME* 160, 140-149.
- Towler, B.F. and Mokhatab, S. (2005). Quickly Estimate Hydrate Formation Conditions in Natural Gases. *Hydrocarbon Processing* 84(4), 61-62.
- Hammerschmidt, E.G. (1934). Formation of Gas Hydrates in Natural Gas Transmission Lines. *Ind. Eng. Chem.* 26(8), 851-855.
- Nielsen, R.B. and Bucklin, R.W. (1983). Why Not Use Methanol for Hydrate Control? *Hydrocarbon Processing* 62(4), 71-78.
- Oddo, J.E. and Tomson, M.B. (1994). Why Scale Forms in the Oil Field and Methods To Predict It. *SPE Production & Facilities* 9(1), 47-54. SPE-21710-PA.
- de Waard, C. and Milliams, D.E. (1975). Carbonic Acid Corrosion of Steel. *Corrosion* 31(5), 177-181.
- de Waard, C., Lotz, U. and Milliams, D.E. (1991). Predictive Model for CO2 Corrosion Engineering in Wet Natural Gas Pipelines. *Corrosion* 47(12), 976-985 (CORROSION/91).
- NACE SP0775. *Preparation, Installation, Analysis, and Interpretation of Corrosion Coupons in Oilfield Operations*. NACE International.
- API RP 14E (1991), *Design and Installation of Offshore Production Platform Piping Systems*, 5th ed., section 2.5.
- GPSA (2012), *Engineering Data Book*, 13th ed., section 17.

## Inputs

| Input | Unit | Default | Name |
|---|---|---|---|
| Gas rate | MMscf/d | 20 | `FAS_Qg` |
| Oil rate | STB/d | 1,000 | `FAS_Qo` |
| Water rate | bbl/d | 500 | `FAS_Qw` |
| Gas specific gravity (air = 1) | — | 0.7 | `FAS_SG` |
| Liquid specific gravity, oil and water blended | — | 0.89 | `FAS_SGL` |
| CO2 mole fraction in the gas | % | 3 | `FAS_CO2` |
| H2S in the gas | ppm | 500 | `FAS_H2S` |
| In-situ pH of the produced water | pH | 5.0 | `FAS_Ph` |
| Wellhead pressure, absolute | psia | 1,000 | `FAS_P` |
| Arrival pressure at the facility, absolute | psia | 740.7 | `FAS_Parr` |
| Wellhead temperature | F | 150 | `FAS_Tin` |
| Arrival temperature, the coldest point | F | 45 | `FAS_Tarr` |
| Seabed temperature, which the line cools toward | F | 40 | `FAS_Tsea` |
| Flowline length along the route | ft | 26,830 | `FAS_L` |
| Shut-in settle-out pressure, absolute | psia | 1,000 | `FAS_Pshut` |
| Flowline bore | in | 6 | `FAS_Bore` |
| Margin off the hydrate curve the line must keep | F | 3 | `FAS_Margin` |
| Methanol in the free water | wt % | 30 | `FAS_MeOH` |
| Methanol vapour-to-liquid ratio, from the GPSA chart | lb/MMscf per wt % | 1 | `FAS_Ratio` |
| Reservoir temperature | F | 200 | `FAS_TRes` |
| Reservoir pressure, absolute | psia | 3,000 | `FAS_PRes` |
| CO2 partial pressure at the reservoir | psia | 50 | `FAS_CO2Res` |
| Separator temperature | F | 100 | `FAS_TSurf` |
| Separator pressure, absolute | psia | 150 | `FAS_PSurf` |
| CO2 partial pressure at the separator | psia | 5 | `FAS_CO2Surf` |
| Temperature where the waters arrive mixed | F | 120 | `FAS_TMix` |
| Pressure where they arrive mixed, absolute | psia | 1,000 | `FAS_PMix` |
| CO2 partial pressure there | psia | 10 | `FAS_CO2Mix` |
| Injection water in the design mix, by volume | % | 50 | `FAS_Frac` |
| Calcium, magnesium, strontium, barium, sulfate and bicarbonate in the formation water | mg/L | 2,000, 300, 300, 250, 10, 500 | `FAS_CaF`, `FAS_MgF`, `FAS_SrF`, `FAS_BaF`, `FAS_SO4F`, `FAS_HCO3F` |
| Ionic strength of the formation water | mol/L | 1.3 | `FAS_IonF` |
| Calcium, magnesium, strontium, barium, sulfate and bicarbonate in the injection water | mg/L | 412, 1,290, 8, 0.01, 2,712, 142 | `FAS_CaI`, `FAS_MgI`, `FAS_SrI`, `FAS_BaI`, `FAS_SO4I`, `FAS_HCO3I` |
| Ionic strength of the injection water | mol/L | 0.7 | `FAS_IonI` |
| Water rate treated | bbl/d | 5,000 | `FAS_QwS` |
| Water specific gravity | — | 1.05 | `FAS_SGw` |
| Minimum inhibitor concentration from its test | ppm | 15 | `FAS_MIC` |
| Inhibitor product specific gravity | — | 1.1 | `FAS_SGi` |
| Highest saturation index the test qualified it at | — | 3 | `FAS_SIQual` |
| Corrosion inhibitor efficiency | % | 85 | `FAS_Eff` |
| Design life | y | 20 | `FAS_Life` |
| Corrosion allowance for carbon steel | mm | 3 | `FAS_CAmax` |
| Sand or other solids produced (1 = yes, 0 = no) | — | 0 | `FAS_Sand` |
| Continuous service (1 = yes, 0 = no) | — | 1 | `FAS_Cont` |
| Corrosive gas and not inhibited (1 = yes, 0 = no) | — | 1 | `FAS_Corr` |
| Consequence of hydrates blocking the line, of scale in the produced water, of CO2 corrosion of the line and of erosion of the line | — | 4, 2, 3, 2 | `FAS_CHyd`, `FAS_CScale`, `FAS_CCorr`, `FAS_CEro` |

## Sheets

- `Guide` — what the workbook decides, as five questions and how each is answered, the workflow and the default system.
- `System` — the one block of inputs every threat reads: the stream, the line from the wellhead to the arrival, the waters at the reservoir, the separator and the mix, the formation and injection water analyses, the scale inhibitor, the corrosion management, the erosion service and each threat's consequence.
- `Hydrates` — the hydrate point at the wellhead, arrival and shut-in pressures, the inhibitor's depression and dose, the line's path over 21 stations, and a chart of the hydrate curve, bare and with the methanol, against the flowing line.
- `Scale` — the mixing table from formation water to injection water, the calcite, barite and celestite saturation indices (screening values) with a chart against the injection water's share, and the continuous inhibitor's dose.
- `Corrosion` — the de Waard-Milliams CO2 rate of bare carbon steel, the inhibited rate, the wall lost over the design life against the allowance, the sour-service region and the first-pass material.
- `Erosion` — the gas at line conditions, the API RP 14E erosional velocity against the mixture velocity in the line's bore, and their ratio.
- `Risk` — each threat's likelihood from its computed margin, its consequence, and the register that rates each score Low to Critical.
- `Summary` — every headline from the system's sheets, every check and the system's one verdict.
- `Test Cases` — the worked example and other cases, with expected and computed results.

## Functions used

`PO.FA.Hydrate.Teq`, `PO.FA.Hydrate.dTsub`, `PO.FA.Hydrate.dT.MeOH`, `PO.FA.Hydrate.Conc.MeOH`, `PO.FA.Hydrate.Conc.MEG`,
`PO.FA.Hydrate.Qinj.MeOH`, `PO.FA.Hydrate.Qinj.MEG`, `PO.FA.Scale.SI.OddoTomson`, `PO.FA.Scale.MixRatio`,
`PO.FA.Scale.InhibitorDose`, `PO.FA.Corrosion.Pp.CO2`, `PO.FA.Corrosion.CR.CO2`, `PO.FA.Corrosion.CR.Inh`,
`PO.FA.Corrosion.Severity`, `PO.FA.Corrosion.CA`, `PO.FA.Corrosion.H2S.Region`, `PO.HSE.Sour.PartialPressure`,
`PO.CO.Mat.CO2Material`, `PO.FA.Erosion.RhoMix`, `PO.FA.Erosion.Vmix`, `PO.FA.Erosion.CFactor`, `PO.FA.Erosion.Ve`,
`PO.FA.Erosion.Ratio`, `PO.FA.Erosion.Risk`, `PO.PVT.Ppc.ByStanding.Sour`, `PO.PVT.Tpc.ByStanding.Sour`, `PO.PVT.Z.ByDAK`,
`PO.PVT.Bg.ByDefinition`, `PO.PVT.Rho.Gas.ByDefinition`, `PO.PVT.Rho.Wat.Stn`, `PO.UnitConverter`.