id: po.wb.esp.design
title: ESP System Design
summary: "How many stages and which motor one well's ESP needs, where it operates, and whether intake gas, cable voltage drop and drive speed are acceptable."
category: Production
requires:
  - po-addin
  - excel-365
tags:
  - esp
  - pump-sizing
  - gas-handling
  - cable-sizing
  - vsd
---

## Description

Which pump stages and motor does one well's electric submersible pump need, and will the installation run? You enter the well's depths, reservoir pressure, productivity index and design rate, the fluid, the cable and the drive frequencies. You read off the stages and motor, the operating point where the pump head crosses the system curve, the free gas at the intake and the separator it calls for, the cable voltage drop, and the drive frequency that delivers a target rate.

**How to use it:** Enter the well, fluid, motor limits and design rate on the Operating sheet, and replace its synthetic single-stage pump curve and motor list with verified vendor data, in increasing rate and rating order. Enter the oil share, GOR, gravities and separator on the Gas sheet, the surface run, cable size, conductor, allowed voltage drop and deviation allowance on the Cable sheet, and the drive frequencies and target rate on the VSD sheet. Resolve every check on the Summary, and confirm gas handling, cable ampacity and motor cooling with the vendor.

**Method:** The operating sheet uses the linear productivity index and the pump intake pressure to calculate the system head, and interpolates the unique crossing of the pump and system curves on a 41-point grid. The gas sheet takes the fluid at the intake from Standing's, McCain's and Dranchuk–Abou-Kassem's correlations, finds the free-gas void fraction before and after the separator, and screens it against what a standard pump (up to 10 % free gas) and gas-handler stages (up to 25 %) take, with Turpin's factor alongside. The cable sheet estimates the resistive three-phase voltage drop and power loss of the chosen cable and the smallest size that keeps the drop within the allowance. The variable-speed sheet moves the same pump curve by the affinity laws (rate with frequency, head with its square, power with its cube) and interpolates the target frequency between operating points.

**Example:** The operating-point blueprint's default well has pump depth 6,800 ft, mid-perforations 7,500 ft, reservoir pressure 2,800 psi, productivity index 2.5 STB/d/psi and a 1,600 STB/d design rate. On its synthetic 60 Hz pump curve it needs 101 stages and produces 1,612.35 STB/d at 2,633.31 ft of system head, the same numbers the ESP operating-point blueprint gives on the same inputs. The pump curve and motor data are not vendor specifications.

## Validity

The pump and motor data are generated screening examples, not sourced vendor equipment; replace them with verified equipment data before design. A sourced vendor-equipment catalog is not yet included. Use measured well test and PVT data and consult the vendor on pump gas tolerance, motor cooling, starting voltage and cable ampacity. The gas model assumes no slip and uses screening separator efficiencies; the cable drop is resistive only and its minimum-size calculation is for copper. The zero deviation allowance assumes the pump's measured depth equals its true vertical depth; enter measured depth minus true vertical depth for a deviated well. The gas pressure-sensitivity and cable-size comparison charts are left out here; use the individual blueprints for those details. The drive frequency is interpolated, not optimised; the add-in has no optimum-frequency function.

## References

- Takacs, G. (2009). *Electrical Submersible Pumps Manual: Design, Operations, and Maintenance*. Gulf Professional Publishing.
- American Petroleum Institute. *API RP 11S4, Recommended Practice for Sizing and Selection of Electric Submersible Pump Installations*.
- Standing, M.B. (1947). A Pressure-Volume-Temperature Correlation for Mixtures of California Oils and Gases. *Drilling and Production Practice*, API, 275-287.
- McCain, W.D. Jr. (1990). *The Properties of Petroleum Fluids*, 2nd ed. PennWell.
- Dranchuk, P.M. and Abou-Kassem, J.H. (1975). Calculation of Z Factors for Natural Gases Using Equations of State. *J. Can. Pet. Tech.* 14(3), 34-36.
- Turpin, J.L., Lea, J.F. and Bearden, J.L. (1986). Gas-Liquid Flow Through Centrifugal Pumps: Correlation of Data. *Proceedings of the Third International Pump Symposium*, Texas A&M University.

## Inputs

| Input | Unit | Default | Name |
|---|---|---|---|
| Pump setting depth (TVD) | ft | 6800 | `EDO_Dpump` |
| Mid-perforation depth (TVD) | ft | 7500 | `EDO_Dperf` |
| Static reservoir pressure | psi | 2800 | `EDO_Pr` |
| Productivity index | STB/d/psi | 2.5 | `EDO_PI` |
| Design liquid rate | STB/d | 1600 | `EDO_Q` |
| Liquid specific gravity | — | 0.94 | `EDO_SG` |
| Wellhead pressure | psi | 150 | `EDO_WHP` |
| Tubing ID | in. | 2.992 | `EDO_TubID` |
| Tubing length | ft | 6800 | `EDO_TubL` |
| Casing ID at the motor | in. | 6.276 | `EDO_CasingID` |
| Stages installed (0 = as required) | stages | 0 | `EDO_StagesSet` |
| Motor sizing safety factor | — | 1.1 | `EDO_SF` |
| Motor efficiency | % | 85 % | `EDO_MotorEff` |
| Motor power factor | — | 0.82 | `EDO_PF` |
| Motor OD | in. | 4.56 | `EDO_MotorOD` |
| Fluid temperature at the motor | °F | 180 | `EDO_T` |
| BEP window, low and high fraction | % | 80 %, 120 % | `EDO_BepLo`, `EDO_BepHi` |
| Minimum and maximum motor load | % | 70 %, 100 % | `EDO_LoadMin`, `EDO_LoadMax` |
| Minimum desired submergence | ft | 500 | `EDO_MinSubm` |
| Synthetic single-stage pump curve at 60 Hz: rate, head, efficiency | STB/d, ft/stage, % | generated example | `EDO_CurveQ`, `EDO_CurveH`, `EDO_CurveE` |
| Synthetic motor list: rating, voltage | hp, V | generated example | `EDO_MotorHPs`, `EDO_MotorVs` |
| Oil share of surface liquid rate | % | 60 % | `EDG_OilShare` |
| Producing gas-oil ratio | scf/STB | 600 | `EDG_GOR` |
| Oil gravity | °API | 35 | `EDG_API` |
| Gas specific gravity | — | 0.75 | `EDG_SGg` |
| Separator (standard, advanced or tandem) | — | standard | `EDG_SepType` |
| Free gas a standard pump takes, up to | % | 10 % | `EDG_VoidStd` |
| Free gas gas-handler stages take, up to | % | 25 % | `EDG_VoidAgh` |
| Surface cable run | ft | 200 | `EDC_SurfaceRun` |
| Cable size chosen | AWG | 1 | `EDC_AWG` |
| Conductor (copper or aluminum) | — | copper | `EDC_Material` |
| Voltage drop allowed, share of motor volts | % | 5 % | `EDC_MaxDrop` |
| Extra downhole cable length (MD minus TVD) | ft | 0 | `EDC_DeviationExtra` |
| Catalog frequency | Hz | 60 | `EDV_Fb` |
| Drive frequencies F1 to F4 | Hz | 40, 50, 60, 70 | `EDV_F1`, `EDV_F2`, `EDV_F3`, `EDV_F4` |
| Target liquid rate | STB/d | 1800 | `EDV_Qt` |

## Sheets

- `Guide` — the workflow through the sheets, and why the example equipment is synthetic and must be replaced with vendor data.
- `Operating` — the well and fluid, the pump, motor and limits, the synthetic 60 Hz pump curve and motor list, the stages and motor chosen, the operating point and motor load, and the pump and system curves charted at 60 Hz.
- `Gas` — the operating point at the intake, the fluid there, the free gas before and after the separator, and the gas-handling call.
- `Cable` — the motor and cable length, the current, the chosen cable's voltage drop and power loss, and the smallest cable that meets the allowance.
- `VSD` — the drive frequencies and target rate, the target frequency and its performance, the operating envelope, and the pump curves at each frequency against the system curve.
- `Summary` — the selected design and every check under one verdict.
- `Test Cases` — the worked example and other cases, with expected and computed results.

## Functions used

Operating: `PO.ESP.Nodal.Psuction`, `PO.ESP.Nodal.Drawdown`, `PO.ESP.Nodal.Submergence`, `PO.ESP.System.Hfric`, `PO.ESP.TDH`, `PO.ESP.Pump.TotalHead`, `PO.ESP.Pump.Pdis`, `PO.ESP.Curve.Head`, `PO.ESP.Curve.Efficiency`, `PO.ESP.Curve.BEP`, `PO.ESP.Curve.BEP.Eff`, `PO.ESP.Curve.Range.Status`, `PO.ESP.Stages`, `PO.ESP.Stages.Actual`, `PO.ESP.HydraulicHP`, `PO.ESP.BrakeHP`, `PO.ESP.BrakeHP.FromRate`, `PO.ESP.Motor.RequiredHP`, `PO.ESP.Motor.LoadFactor`, `PO.ESP.Motor.Load.Status`, `PO.ESP.Motor.Amps`, `PO.ESP.Motor.PowerKW`, `PO.ESP.Motor.Qcool`, `PO.ESP.Motor.Temp.Rise`. Gas: `PO.PVT.Pb.ByStanding`, `PO.PVT.Rs.ByStanding`, `PO.PVT.Bo.Sat.ByStanding`, `PO.PVT.Bw.ByMcCain`, `PO.PVT.Ppc.ByStanding`, `PO.PVT.Tpc.ByStanding`, `PO.PVT.Z.ByDAK`, `PO.PVT.Bg.ByDefinition`, `PO.ESP.Gas.Ql.Total`, `PO.ESP.Gas.Qg.Free`, `PO.ESP.Gas.Void`, `PO.ESP.Gas.Void.Full`, `PO.ESP.Gas.Void.PostSep`, `PO.ESP.Gas.Sep.Eff`, `PO.ESP.Gas.Turpin.Factor`, `PO.ESP.Gas.Recommendation`. Cable: `PO.ESP.Cable.Resistance`, `PO.ESP.Cable.Vdrop`, `PO.ESP.Cable.Vdrop.Pct`, `PO.ESP.Cable.Vdrop.Status`, `PO.ESP.Cable.Vmotor`, `PO.ESP.Cable.Vsurface`, `PO.ESP.Cable.PowerLoss`, `PO.ESP.Cable.PowerLoss.Pct`, `PO.ESP.Cable.MinSize`. VSD (catalog LAMBDAs): `PO.ESP.Affinity.Rate`, `PO.ESP.Affinity.Head`, `PO.ESP.Affinity.Power`. `PO.UnitConverter`.