summary: "How to kill a kick and how big a kick the shoe takes: kill sheet, kick tolerance, MAASP, bullheading limits and BOP accumulator sizing."
category: Drilling
requires:
  - excel-365
tags:
  - drilling
  - well-control
  - kill-sheet
  - wait-and-weight
  - drillers-method
  - kick
  - kill-mud-weight
  - ICP
  - FCP
  - MAASP
  - strokes
  - kick-tolerance
  - bullheading
  - accumulator
  - BOP
  - precharge
  - boyles-law
---

## Description

What does the driller post to kill this kick, how big a kick can the shoe take, can the kick be bullheaded, and will the accumulator close the stack? You enter the well, string, mud, pump and slow circulating rate pressure, then SIDPP, SICP and the pit gain once shut in, the kick zone and the stack's bottles. You read off the kill mud weight, ICP, FCP, strokes, MAASP and the drill pipe pressure schedule, the kick tolerance across kick intensities, the bullheading limit and losses, and the bottles needed with the precharge window. Field units; no add-in needed.

**How to use it:** The kick, well and stack are made up. On the Kill Sheet, enter the rig's string, the mud, the pump and the slow circulating rate pressure recorded on the rig before drilling out; once the well is shut in and stable, enter the stabilised shut-in pressures and the pit gain, and pick Wait & Weight or Driller's from the list. On Kick Tolerance set the design kick intensity, the influx gradient and the plan's minimum; on Bullheading the kick zone from offset logs or a test; on Accumulator the stack's own data sheet over the typical volumes, with the functions picked by name. The Summary lists what the driller posts and every check under one verdict.

**Method:** Kill mud = MW + SIDPP / (0.052 TVD), rounded up to 0.1 ppg; ICP = SIDPP + SCR pressure; FCP = SCR × KMW / MW; MAASP = (LOT EMW − MW) 0.052 shoe TVD. The annulus is six sections, each string component against open hole and casing; the influx fills the open hole up from the bit, and its gradient 0.052 MW − (SICP − SIDPP) / height reads gas below 0.25 psi/ft and water from 0.40. Wait & Weight drops drill pipe pressure from ICP to FCP in ten steps while kill mud fills the string; the Driller's method first holds ICP for one circulation. Kick tolerance: the shoe allows an influx height H = (MAASP − 0.052 KI TVD) / (0.052 MW − G), with KI the kick intensity and G the influx gradient; the kick tolerance is the smaller of H around the BHA at the bit and H around the drill pipe below the shoe taken back to bottom-hole pressure by Boyle's law. Bullheading: the shoe's fracture pressure less the hydrostatic above it, falling as kill mud fills the cased annulus; losses to the kick zone are steady radial Darcy flow. Accumulator: usable fluid per bottle Vb (Pre/Pmin − Pre/Pmax), with Vb the bottle's nitrogen volume and Pre, Pmin and Pmax the precharge, minimum and full operating pressures; bottles for the functions times the design factor, and the precharge window. Every formula is a catalog LAMBDA in the Name Manager.

**Example:** The kill sheet blueprint's made-up kick: 15 bbl at 12,500 ft MD / 11,800 ft TVD in 11.2 ppg mud, SIDPP 420 psi, SICP 610 psi, 9⅝-in. shoe at 8,200 ft TVD with a 14.8 ppg leak-off. Kill mud 11.9 ppg, ICP 1,070 psi, FCP 691 psi, 2,070 strokes to the bit (69 min at 30 spm) and 7,848 for a circulation, where the Driller's kill mud starts. MAASP 1,535 psi, 1,237 psi with kill mud; the 515 ft influx at 0.21 psi/ft reads as gas. At 0.5 ppg the kick tolerance is 102.7 bbl (Boyle's law at the shoe governs; 106.8 bbl at the bit), 134.1 bbl at no intensity, 47.4 bbl at 1.5 ppg and 19.2 bbl at 2 ppg, where the bit governs; the kick's own 0.68 ppg is under the 2.10 ppg the shoe takes with 15 bbl. MAASP falls to 43 psi at 14.7 ppg. Bullheading may start at 1,535 psi; 910 psi passes, the zone takes 12.2 bbl/hr and loses 0.39 bbl/hr of kill mud. The 13⅝-in. stack needs 41.48 gal, 62.22 gal with the 1.5 factor: 13 of the 16 bottles, 1,688 psi left after one sequence, precharge window 778–1,000 psi, the test reads 997 psi.

## Validity

A vertical or near-vertical well: hydrostatics use TVD and the schedule falls linearly with strokes, so a deviated well needs a schedule by section. One influx bubble at the bottom, no migration while shut in, ideal isothermal gas for the kick tolerance; a height past the shoe is flagged. Bullheading takes no friction or migration and steady radial losses with no filter cake (an upper bound). The function volumes are typical published values, not the rig's. Named alternatives: lubricate-and-bleed where bullheading would exceed the shoe or the wellhead; a deviated-well schedule; a dynamic kick simulator for a horizontal well. The add-in has no functions for these.

## References

- Bourgoyne, A.T. et al. (1986). *Applied Drilling Engineering*. SPE Textbook Series Vol. 2, ch. 4.
- Watson, D., Brittenham, T. and Moore, P.L. (2003). *Advanced Well Control*. SPE Textbook Series Vol. 10.
- Grace, R.D. (1994). *Advanced Blowout and Well Control*. Gulf Publishing.
- Lapeyrouse, N.J. *Formulas and Calculations for Drilling, Production and Workover*. Gulf Professional Publishing, ch. 4 (kick tolerance, bullheading, accumulator precharge test).
- API Standard 53 (2018). *Well Control Equipment Systems for Drilling Wells* (accumulator sizing and precharge).

## Inputs

| Input | Unit | Default | Name |
|---|---|---|---|
| Bit depth MD and TVD, shoe MD and TVD | ft | 12500, 11800, 8500, 8200 | `KIL_MD`, `KIL_TVD`, `KIL_ShoeMD`, `KIL_ShoeTVD` |
| Original mud weight | ppg | 11.2 | `KIL_MW` |
| Leak-off test at the shoe, as an equivalent mud weight | ppg | 14.8 | `KIL_LOT` |
| Pump output at the running efficiency | bbl/stk | 0.102 | `KIL_PumpOut` |
| Kill rate | spm | 30 | `KIL_SPM` |
| Slow circulating rate pressure at the kill rate | psi | 650 | `KIL_Pscr` |
| Shut-in drill pipe pressure (SIDPP) | psi | 420 | `KIL_SIDPP` |
| Shut-in casing pressure (SICP) | psi | 610 | `KIL_SICP` |
| Pit gain | bbl | 15 | `KIL_Gain` |
| Kill method, from a list | — | Wait & Weight | `KIL_Method` |
| Kick intensity: formation pressure over the mud weight | ppg | 0.5 | `KTL_KI` |
| Influx gradient to design for (0.1 psi/ft is gas) | psi/ft | 0.1 | `KTL_Ginf` |
| Kick tolerance the well plan requires | bbl | 25 | `KTL_KTmin` |
| Pressure over the SICP to start injecting into the kick zone | psi | 300 | `BHD_BHover` |
| Permeability of the kick zone | mD | 50 | `BHD_Perm` |
| Height of the kick zone open to the hole | ft | 20 | `BHD_Hzone` |
| Bottle nitrogen volume (an 11 gal bottle holds 10) | gal | 10 | `ACU_Vb` |
| Nitrogen precharge pressure | psi | 1000 | `ACU_Pre` |
| Minimum operating pressure | psi | 1200 | `ACU_Pmin` |
| Accumulator operating pressure (fully charged) | psi | 3000 | `ACU_Pmax` |
| Bottles installed | — | 16 | `ACU_N` |
| Design factor on the required volume | — | 1.5 | `ACU_SF` |

## Sheets

- `Guide` — what the workbook answers and the order to work through its sheets.
- `Kill Sheet` — the well, the string, the mud, the pump and the slow circulating rate pressure, then SIDPP, SICP and the pit gain; the kill mud weight, ICP and FCP, strokes and time, MAASP, the influx height and gradient, and the drill pipe pressure schedule for the method picked from a list (Wait & Weight or Driller's), charted.
- `Kick Tolerance` — the largest kick the shoe can take at the design kick intensity, the kick's own intensity against what the shoe can take, the kick tolerance across kick intensities against the plan's minimum, and MAASP as the mud is weighted up.
- `Bullheading` — the shoe's limit on surface pressure, the rate the kick zone takes and the kill mud lost to it.
- `Accumulator` — the bottles sized by Boyle's law for the stack's functions, picked by name from typical volumes, with the precharge window, a precharge test and the pressure as fluid is drawn.
- `Summary` — what the driller posts and every check under one verdict.
- `Test Cases` — the worked example and other cases, with expected and computed results.

Three charts: the drill pipe pressure schedule, the kick tolerance against kick intensity, and the accumulator pressure against fluid drawn.

## Functions used

Catalog LAMBDAs: `PO.DE.PipeCapacity`, `PO.DE.AnnularCapacity`, `PO.DE.Hydrostatic`, `PO.DE.WellControl.KillMudWeight`, `.ICP`, `.FCP`, `.MAASP`, `.InfluxGradient`, `PO.DE.PressureToBreakCirculation`, `PO.DE.KickTol.Volume`, `PO.DE.KickTol.Intensity`, `PO.WI.Kill.Bullhead`, `PO.WI.Kill.FluidLoss`, `PO.DE.Accumulator.UsableVolume`, `.PressureAfterDraw`, `PO.DE.BOP.ClosingVolume` and `PO.DE.BOP.Precharge`, with the `_PO.DE.IntervalOverlap` helper.