# Gas-Lift Valve Throughput

## Description

How much gas does a gas-lift port pass, and does that rate hold when the tubing pressure moves? You enter the port's discharge coefficient and diameter, the valve's bellows area, the casing and tubing pressures and gas temperature at the valve, the gas gravity and specific heat ratio, and the design rate. You read off the Thornhill-Craver throughput, the pressure ratio against the critical ratio, the choked rate, the rate lost per 10 psi of tubing pressure and the production pressure effect factor.

**Parameters:**
- **Port**: discharge coefficient, port diameter and the valve's bellows area (`GLT_Cd`, `GLT_dPort`, `GLT_Ab`)
- **At the valve**: upstream casing and downstream tubing pressures and the gas temperature (`GLT_P1`, `GLT_P2`, `GLT_T`)
- **Gas**: specific gravity and specific heat ratio (`GLT_SG`, `GLT_k`, 1.28 for natural gas)
- **Design rate**: the gas the port must pass (`GLT_Qgi`)

**How to use it:** Type the casing and tubing pressures at your operating valve and its temperature, from the design sheets or a flowing survey, and your port and bellows area from the valve catalogue. Thornhill-Craver is a square-edged orifice; a valve's own flow test (API RP 11V2) gives a better Cd, often 0.6–0.9 depending on the seat. Check that the port passes the design rate, and whether the flow is critical. A curve draws the throughput against the casing-to-tubing differential, from a small differential to sonic flow, with the operating point marked: the choked rate is the most the port can pass at this casing pressure.

**Method:** Thornhill-Craver (Guo et al. 2007, Eq. 13.16) gives the gas rate through a port, Qg = 1248·Cd·Ap·P1·√{k/((k − 1)·γg·T)·[(P2/P1)^(2/k) − (P2/P1)^((k+1)/k)]} in Mscf/d, with Ap = π·d²/4. Below the critical pressure ratio rc = (2/(k + 1))^(k/(k − 1)), 0.549 at k = 1.28, the flow is sonic and the rate no longer depends on P2: the function holds the ratio at rc there. The choked rate is the throughput at any tubing pressure below rc·P1. The curve runs P2/P1 from 0.30 to 0.98 at the given casing pressure. The sensitivity is the rate lost when the tubing pressure rises 10 psi.

The production pressure effect factor, PPEF = R/(1 − R) with R = Ap/Ab, is how much the tubing pressure lowers an unbalanced IPO valve's opening pressure: Pvo = Pd/(1 − R) − PPEF·Pt. It matters for an unloading valve, whose opening pressure moves with the tubing pressure under it, and for setting it on the test rack; it does not enter the orifice's throughput. A large port has a large R: a 32/64-in port in a 1½-in valve has R ≈ 0.25 and a PPEF of 0.34, so every 100 psi of tubing pressure lowers its opening pressure by 34 psi. The Gas-Lift Valve Setting sheet takes it into the dome charge.

**Example:** The well (GL-1) and its 16/64-in operating port are the ones the Gas-Lift Injection Pressure and Point of Injection and Gas-Lift Valve Setting sheets design: 1,181 psia casing and 1,080.5 psia tubing at the valve at 7,154 ft and 187 °F, 0.65-gravity lift gas, and a design rate of 500 Mscf/d.

The 16/64-in port has 0.0491 in², R = 0.0638 and PPEF = 0.068 in a valve with a 0.77 in² bellows. At 1,181 psia casing and 1,080.5 psia tubing, P2/P1 = 0.915, well above the critical 0.549, so the flow is subcritical. The port passes 586 Mscf/d, more than the design 500 Mscf/d. That is 59 % of the 994 Mscf/d it would pass choked, below 649 psia tubing. In this subcritical flow the rate falls 27 Mscf/d for every 10 psi the tubing pressure rises, so the critical-flow check warns. A 100 psi differential leaves the injection sensitive to tubing-pressure swings; designs that want a steady rate choke the port at a larger differential or use a venturi orifice.

The sheet was checked against Guo, Lyons and Ghalambor (2007) Example 13.6, which sizes a port for 2,500 Mscf/d at Cd 0.6, 900 psia upstream and 600 psia downstream, γg 0.75, 570 °R and k 1.3, and finds 0.1684 in². Set to those values, with the port diameter of that area (0.463048 in), the sheet returns the 2,500 Mscf/d within 0.5 %. At k 1.3 the critical ratio is 0.546, below the example's 0.667, so the example is subcritical too.

## Validity

Single-phase gas through a square-edged orifice, as Thornhill and Craver measured it; a valve with a large port or a short stem travel throttles below the orifice rate, and its own flow test (API RP 11V2) is the better model. The critical ratio holds for an ideal gas with constant k. The temperature is the gas temperature at the valve; the gravity and k are those of the lift gas. Thornhill-Craver says nothing about whether the valve is open; the Gas-Lift Valve Setting sheet decides that.

Named alternatives: a valve's API RP 11V2 flow-coefficient model for throttling IPO valves, a venturi (nozzle) orifice, which reaches critical flow at a much smaller differential and so holds the rate, and the dome-charge balance itself on the Gas-Lift Valve Setting sheet.

## References

- Guo, B., Lyons, W.C. and Ghalambor, A. (2007). *Petroleum Production Engineering: A Computer-Assisted Approach*. Gulf Professional Publishing, Ch. 13 (gas lift), Eq. 13.16, Example 13.6, §13.5.2.1.
- Brown, K.E. (1980). *The Technology of Artificial Lift Methods*, Vol. 2a. PennWell (gas-lift valve mechanics and throughput).
- API RP 11V2. *Recommended Practice for Gas-Lift Valve Performance Testing*.

## Functions used

`PO.GL.Valve.ThornhillCraver`, `PO.GL.Valve.PPE`

## Spreadsheet: GlValveThroughput

|    | A                                                                                                                                  | B                                                                                                                         | C                                                                                                                                                                                                                                                                                                                                                       | D                                                                                |
|----|------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------|
| 1  | Gas-Lift Valve Throughput                                                                                                          |                                                                                                                           | Petroleum Office                                                                                                                                                                                                                                                                                                                                        |                                                                                  |
| 2  | Blue cells on yellow are inputs. The casing and tubing pressures at the valve come from the gas-lift design sheets.                |                                                                                                                           |                                                                                                                                                                                                                                                                                                                                                         |                                                                                  |
| 4  | Port and Pressures at the Operating Valve                                                                                          |                                                                                                                           |                                                                                                                                                                                                                                                                                                                                                         |                                                                                  |
| 5  | Discharge coefficient                                                                                                              | 0.6                                                                                                                       | —                                                                                                                                                                                                                                                                                                                                                       |                                                                                  |
| 6  | Port diameter (16/64 in)                                                                                                           | 0.25                                                                                                                      | in                                                                                                                                                                                                                                                                                                                                                      |                                                                                  |
| 7  | Valve bellows area                                                                                                                 | 0.77                                                                                                                      | in²                                                                                                                                                                                                                                                                                                                                                     |                                                                                  |
| 8  | Upstream (casing) pressure at the valve                                                                                            | 1181                                                                                                                      | psi                                                                                                                                                                                                                                                                                                                                                     |                                                                                  |
| 9  | Downstream (tubing) pressure at the valve                                                                                          | 1080.5                                                                                                                    | psi                                                                                                                                                                                                                                                                                                                                                     |                                                                                  |
| 10 | Lift-gas specific gravity                                                                                                          | 0.65                                                                                                                      | air = 1                                                                                                                                                                                                                                                                                                                                                 |                                                                                  |
| 11 | Gas temperature at the valve                                                                                                       | 187                                                                                                                       | °F                                                                                                                                                                                                                                                                                                                                                      |                                                                                  |
| 12 | Lift-gas specific heat ratio, Cp/Cv                                                                                                | 1.28                                                                                                                      | —                                                                                                                                                                                                                                                                                                                                                       |                                                                                  |
| 13 | Design injection gas rate                                                                                                          | 500                                                                                                                       | Mscf/d                                                                                                                                                                                                                                                                                                                                                  |                                                                                  |
| 14 | Rankine at 0 °F                                                                                                                    | 459.67                                                                                                                    | °R                                                                                                                                                                                                                                                                                                                                                      |                                                                                  |
| 16 | Throughput against Differential                                                                                                    |                                                                                                                           |                                                                                                                                                                                                                                                                                                                                                         |                                                                                  |
| 17 | How to use it: type the casing and tubing pressures at your valve; the curve runs P2/P1 from 0.30 to 0.98 at your casing pressure. |                                                                                                                           |                                                                                                                                                                                                                                                                                                                                                         |                                                                                  |
| 18 | P2/P1                                                                                                                              | Tubing, P2 (psi)                                                                                                          | Differential (psi)                                                                                                                                                                                                                                                                                                                                      | Throughput (Mscf/d)                                                              |
| 19 | 0.3                                                                                                                                | =A19*GLT_P1                                                                                                               | =GLT_P1-B19                                                                                                                                                                                                                                                                                                                                             | =PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,B19,GLT_SG,GLT_T+GLT_R0,GLT_k) |
| 20 | 0.4                                                                                                                                | =A20*GLT_P1                                                                                                               | =GLT_P1-B20                                                                                                                                                                                                                                                                                                                                             | =PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,B20,GLT_SG,GLT_T+GLT_R0,GLT_k) |
| 21 | 0.5                                                                                                                                | =A21*GLT_P1                                                                                                               | =GLT_P1-B21                                                                                                                                                                                                                                                                                                                                             | =PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,B21,GLT_SG,GLT_T+GLT_R0,GLT_k) |
| 22 | 0.55                                                                                                                               | =A22*GLT_P1                                                                                                               | =GLT_P1-B22                                                                                                                                                                                                                                                                                                                                             | =PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,B22,GLT_SG,GLT_T+GLT_R0,GLT_k) |
| 23 | 0.6                                                                                                                                | =A23*GLT_P1                                                                                                               | =GLT_P1-B23                                                                                                                                                                                                                                                                                                                                             | =PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,B23,GLT_SG,GLT_T+GLT_R0,GLT_k) |
| 24 | 0.65                                                                                                                               | =A24*GLT_P1                                                                                                               | =GLT_P1-B24                                                                                                                                                                                                                                                                                                                                             | =PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,B24,GLT_SG,GLT_T+GLT_R0,GLT_k) |
| 25 | 0.7                                                                                                                                | =A25*GLT_P1                                                                                                               | =GLT_P1-B25                                                                                                                                                                                                                                                                                                                                             | =PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,B25,GLT_SG,GLT_T+GLT_R0,GLT_k) |
| 26 | 0.75                                                                                                                               | =A26*GLT_P1                                                                                                               | =GLT_P1-B26                                                                                                                                                                                                                                                                                                                                             | =PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,B26,GLT_SG,GLT_T+GLT_R0,GLT_k) |
| 27 | 0.8                                                                                                                                | =A27*GLT_P1                                                                                                               | =GLT_P1-B27                                                                                                                                                                                                                                                                                                                                             | =PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,B27,GLT_SG,GLT_T+GLT_R0,GLT_k) |
| 28 | 0.85                                                                                                                               | =A28*GLT_P1                                                                                                               | =GLT_P1-B28                                                                                                                                                                                                                                                                                                                                             | =PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,B28,GLT_SG,GLT_T+GLT_R0,GLT_k) |
| 29 | 0.9                                                                                                                                | =A29*GLT_P1                                                                                                               | =GLT_P1-B29                                                                                                                                                                                                                                                                                                                                             | =PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,B29,GLT_SG,GLT_T+GLT_R0,GLT_k) |
| 30 | 0.93                                                                                                                               | =A30*GLT_P1                                                                                                               | =GLT_P1-B30                                                                                                                                                                                                                                                                                                                                             | =PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,B30,GLT_SG,GLT_T+GLT_R0,GLT_k) |
| 31 | 0.96                                                                                                                               | =A31*GLT_P1                                                                                                               | =GLT_P1-B31                                                                                                                                                                                                                                                                                                                                             | =PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,B31,GLT_SG,GLT_T+GLT_R0,GLT_k) |
| 32 | 0.98                                                                                                                               | =A32*GLT_P1                                                                                                               | =GLT_P1-B32                                                                                                                                                                                                                                                                                                                                             | =PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,B32,GLT_SG,GLT_T+GLT_R0,GLT_k) |
| 34 |                                                                                                                                    |                                                                                                                           | Differential (psi)                                                                                                                                                                                                                                                                                                                                      | Operating point (Mscf/d)                                                         |
| 35 |                                                                                                                                    |                                                                                                                           | =GLT_P1-GLT_P2                                                                                                                                                                                                                                                                                                                                          | =GLT_Qg                                                                          |
| 37 | Throughput at the Operating Valve                                                                                                  |                                                                                                                           |                                                                                                                                                                                                                                                                                                                                                         |                                                                                  |
| 38 | Port area                                                                                                                          | =PI()*(GLT_dPort/2)^2                                                                                                     | in²                                                                                                                                                                                                                                                                                                                                                     |                                                                                  |
| 39 | Port-to-bellows area ratio, R                                                                                                      | =GLT_Ap/GLT_Ab                                                                                                            | —                                                                                                                                                                                                                                                                                                                                                       |                                                                                  |
| 40 | Production pressure effect factor, R/(1 − R)                                                                                       | =PO.GL.Valve.PPE(GLT_R)                                                                                                   | —                                                                                                                                                                                                                                                                                                                                                       |                                                                                  |
| 41 | Gas throughput, Thornhill-Craver                                                                                                   | =PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,GLT_P2,GLT_SG,GLT_T+GLT_R0,GLT_k)                                       | Mscf/d                                                                                                                                                                                                                                                                                                                                                  |                                                                                  |
| 42 | Pressure ratio, P2/P1                                                                                                              | =GLT_P2/GLT_P1                                                                                                            | —                                                                                                                                                                                                                                                                                                                                                       |                                                                                  |
| 43 | Critical pressure ratio                                                                                                            | =(2/(GLT_k+1))^(GLT_k/(GLT_k-1))                                                                                          | —                                                                                                                                                                                                                                                                                                                                                       |                                                                                  |
| 44 | Tubing pressure below which the port chokes                                                                                        | =GLT_Rc*GLT_P1                                                                                                            | psi                                                                                                                                                                                                                                                                                                                                                     |                                                                                  |
| 45 | Choked (sonic) throughput                                                                                                          | =PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,GLT_P2c/2,GLT_SG,GLT_T+GLT_R0,GLT_k)                                    | Mscf/d                                                                                                                                                                                                                                                                                                                                                  |                                                                                  |
| 46 | Throughput, share of the choked rate                                                                                               | =GLT_Qg/GLT_Qmax                                                                                                          | %                                                                                                                                                                                                                                                                                                                                                       |                                                                                  |
| 47 | Rate lost per 10 psi more tubing pressure                                                                                          | =IF(GLT_P1-GLT_P2>10,GLT_Qg-PO.GL.Valve.ThornhillCraver(GLT_Cd,GLT_Ap,GLT_P1,GLT_P2+10,GLT_SG,GLT_T+GLT_R0,GLT_k),GLT_Qg) | Mscf/d                                                                                                                                                                                                                                                                                                                                                  |                                                                                  |
| 48 | Port capacity check                                                                                                                | =IF(GLT_Qg>=GLT_Qgi,"PASS","FAIL")                                                                                        | =IF(GLT_Qg>=GLT_Qgi,"the port passes "&TEXT(GLT_Qg,"#,##0")&" Mscf/d against the design "&TEXT(GLT_Qgi,"#,##0")&" Mscf/d","the port passes only "&TEXT(GLT_Qg,"#,##0")&" Mscf/d of the design "&TEXT(GLT_Qgi,"#,##0")&": a larger port or a larger differential")                                                                                       |                                                                                  |
| 49 | Critical-flow check                                                                                                                | =IF(GLT_Ratio<=GLT_Rc,"PASS","WARN")                                                                                      | =IF(GLT_Ratio<=GLT_Rc,"P2/P1 "&TEXT(GLT_Ratio,"0.00")&" is at or below the critical "&TEXT(GLT_Rc,"0.00")&": sonic flow, the rate holds whatever the tubing pressure does","P2/P1 "&TEXT(GLT_Ratio,"0.00")&" is above the critical "&TEXT(GLT_Rc,"0.00")&": subcritical, the rate falls "&TEXT(GLT_Loss10,"0")&" Mscf/d per 10 psi of tubing pressure") |                                                                                  |

## Names

| Name | RefersTo | Comment |
|------|----------|---------|
| GLT_Cd | $B$5 | Discharge coefficient |
| GLT_dPort | $B$6 | Port diameter (16/64 in), in |
| GLT_Ab | $B$7 | Valve bellows area, in² |
| GLT_P1 | $B$8 | Upstream (casing) pressure at the valve, psi |
| GLT_P2 | $B$9 | Downstream (tubing) pressure at the valve, psi |
| GLT_SG | $B$10 | Lift-gas specific gravity, air = 1 |
| GLT_T | $B$11 | Gas temperature at the valve, °F |
| GLT_k | $B$12 | Lift-gas specific heat ratio, Cp/Cv |
| GLT_Qgi | $B$13 | Design injection gas rate, Mscf/d |
| GLT_Inputs | $B$5:$B$13 | Discharge coefficient, port diameter and bellows area, casing and tubing pressures, gas gravity, temperature, k and the design gas rate |
| GLT_R0 | $B$14 | Rankine at 0 °F, °R |
| GLT_Ap | $B$38 | Port area, in² |
| GLT_R | $B$39 | Port-to-bellows area ratio, R |
| GLT_PPEF | $B$40 | Production pressure effect factor, R/(1 − R) |
| GLT_Qg | $B$41 | Gas throughput, Thornhill-Craver, Mscf/d |
| GLT_Ratio | $B$42 | Pressure ratio, P2/P1 |
| GLT_Rc | $B$43 | Critical pressure ratio |
| GLT_P2c | $B$44 | Tubing pressure below which the port chokes, psi |
| GLT_Qmax | $B$45 | Choked (sonic) throughput, Mscf/d |
| GLT_Share | $B$46 | Throughput, share of the choked rate, % |
| GLT_Loss10 | $B$47 | Rate lost per 10 psi more tubing pressure, Mscf/d |
| GLT_Results | $B$38:$B$49 | Port area, R and PPEF, throughput, pressure and critical ratios, the choked rate and its share, the sensitivity to tubing pressure, and the checks |
| GLT_Curve | $C$19:$D$32 | Valve Throughput against Differential |

---

## Related Blueprints
- [Gas-Lift Valve Setting](/blueprint/po.gl.valve.setting.md)
- [Gas-Lift Unloading Design](/blueprint/po.gl.unloading.design.md)
- [Gas-Lift Injection Pressure and Point of Injection](/blueprint/po.gl.injection.pressure.md)
- [Gas-Lift Allocation Across Four Wells by Equal Slope](/blueprint/po.gl.allocation.multiwell.md)
- [Wellhead Choke Sizing](/blueprint/po.sf.choke.sizing.md)
- [Compressor Staging and Power](/blueprint/po.sf.compressor.power.md)