cid: po.bp.esp.gas.handling
hub: esp
tags: [ESP, gas, void-fraction, separator, gas-separator, gas-interference, free-gas, pump-intake]
facets: { discipline: production, property: gas-handling, phase: multiphase }
title: ESP Gas Handling at the Pump Intake
summary: "Decides whether an ESP needs a gas separator or gas handler from the free-gas fraction at the pump intake."
slug: po.esp.gas.handling
type: worksheet
---

# ESP Gas Handling at the Pump Intake

## Description

Does an ESP need a gas separator or gas-handler stages? You enter the oil and water rates, the producing GOR, the pump intake pressure and temperature, the oil and gas gravities, the separator type and the free gas a pump can take. You read off Rs, Bo, Bw, z and Bg at the intake, the free gas and the liquid there in reservoir barrels, the free-gas (void) fraction before and after the separator, and the call.

**Parameters:**
- **Production**: oil and water rates and the producing GOR (`GH_Qo`, `GH_Qw`, `GH_GOR`)
- **Intake**: the pump intake pressure and temperature (`GH_PIP`, `GH_T`); the PIP is the ESP sizing sheet's
- **Fluid**: oil gravity and gas gravity (`GH_API`, `GH_SGg`)
- **Separator**: 1 standard, 2 advanced, 3 tandem (`GH_SepType`)
- **Limits**: the free gas a standard pump takes and the free gas gas-handler stages take (`GH_VoidStd`, `GH_VoidAgh`), the thresholds `PO.ESP.Gas.Recommendation` uses

**How to use it:** Type the well's test rates and GOR and the intake pressure from a gauge. When a PVT report gives Rs, Bo and Bg at the intake pressure, those replace the correlations: overwrite the three result cells. Run the ESP Sizing and Operating Point sheet first and type its PIP here, so both sheets describe the same pump depth. A table and a chart show how the free gas grows as the intake pressure falls, which is how deep the pump has to go.

**Method:** The bubble point at the producing GOR is Standing's. Below it, Rs at the intake is Standing's, capped at the GOR; at or above it Rs is the GOR and there is no free gas. Bo is Standing's saturated value at that Rs and Bw is McCain's. The gas z-factor is Dranchuk–Abou-Kassem on Standing's pseudo-critical properties, and Bg = 0.02827·z·T/p ft³/scf. The free gas at the intake is Qo·(GOR − Rs)·Bg in ft³/d, converted to reservoir barrels. The liquid is Qo·Bo + Qw·Bw. The void fraction is the gas over the gas plus liquid; the sheet also computes it from the field rates in one step, and the two agree. The separator's efficiency takes gas out of the stream, leaving the void the pump sees. The check passes below 10 % after the separator. It warns below 25 % (add gas-handler, AGH, stages) and fails above that.

**Example:** The defaults are the well the ESP Sizing and Operating Point sheet sizes: 960 STB/d of oil and 640 STB/d of water (1,600 STB/d of liquid), a GOR of 600 scf/STB, 35 °API oil, gas gravity 0.75, 180 °F, and that sheet's intake pressure of 1,875 psi.

- **Fluid:** the bubble point is 2,463 psi, so there is free gas at the intake. Rs = 433.6 scf/STB, Bo = 1.259 bbl/STB and Bw = 1.030 bbl/STB. z = 0.822, so Bg = 0.02827·0.822·639.67/1,875 = 0.00793 ft³/scf.
- **Free gas:** 960·(600 − 433.6)·0.00793 = 1,267 ft³/d, which is 225.7 rb/d. The liquid is 960·1.259 + 640·1.030 = 1,868 rb/d.
- **Void:** 225.7/(225.7 + 1,868) = 10.8 %, so a separator is recommended. The standard separator takes out 64 %, leaving 3.9 %, which a standard pump takes.

Free gas runs from 0 at the bubble point to 29 % at 1,232 psi, the table shows. With the pump about 1,660 ft shallower, at a 1,200 psi intake, Bg is 0.0131 ft³/scf and the free gas 30.1 %. The standard separator leaves 16.6 %, so gas-handler stages are needed; a tandem separator brings it to 8.5 %.

## Validity

Standing's correlations are for black oils of 16–63 °API below about 7,000 psi; outside that, or for a volatile oil, use PVT data. The void fraction assumes no slip and no gas going up the annulus before the intake, so it is the worst case for a pump without a separator. The separator efficiencies are the function's for each type and grow with the free gas; a vendor's curve replaces them. The 10 % and 25 % limits are screening values. A pump's own gas tolerance depends on its stage design and speed, so treat a WARN as "ask the vendor". When the PIP is near the bubble point the free gas is very sensitive to it.

Named alternatives: the Turpin and Dunbar gas-interference screens. Turpin's factor, from the intake pressure and the bubble point, is shown on the sheet; Dunbar's works from the void fraction.

## References

- Standing, M.B. (1947). A Pressure-Volume-Temperature Correlation for Mixtures of California Oils and Gases. *Drilling and Production Practice*, API.
- McCain, W.D. Jr. (1990). *The Properties of Petroleum Fluids*, 2nd ed. PennWell (Bw).
- Dranchuk, P.M. and Abou-Kassem, J.H. (1975). Calculation of Z Factors for Natural Gases Using Equations of State. *JCPT* 14(3).
- Turpin, J.L., Lea, J.F. and Bearden, J.L. (1986). Gas-Liquid Flow Through Centrifugal Pumps: Correlation of Data. *Proc. Third International Pump Symposium*, Texas A&M.
- Takacs, G. (2009). *Electrical Submersible Pumps Manual*. Gulf Professional Publishing (gas separators and gas handlers).

## Functions used

`PO.PVT.Pb.ByStanding`, `PO.PVT.Rs.ByStanding`, `PO.PVT.Bo.Sat.ByStanding`, `PO.PVT.Bw.ByMcCain`, `PO.PVT.Z.ByDAK`, `PO.PVT.Ppc.ByStanding`, `PO.PVT.Tpc.ByStanding`, `PO.PVT.Bg.ByDefinition`, `PO.UnitConverter`, `PO.ESP.Gas.Qg.Free`, `PO.ESP.Gas.Ql.Total`, `PO.ESP.Gas.Void`, `PO.ESP.Gas.Void.Full`, `PO.ESP.Gas.Turpin.Factor`, `PO.ESP.Gas.Recommendation`, `PO.ESP.Gas.Sep.Eff`, `PO.ESP.Gas.Void.PostSep`

## Spreadsheet: EspGasHandling

|    | A                                                                                                         | B                                                                                                                          | C                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        | D                                                                                                                                                                                        | E                                                                                  | F                                                                                                                                                                         |
|----|-----------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| 1  | ESP Gas Handling at the Pump Intake                                                                       |                                                                                                                            | Petroleum Office                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 2  | Blue cells on yellow are inputs. The well and its intake pressure are the ESP sizing sheet's.             |                                                                                                                            |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 3  | Production, Intake and Fluid                                                                              |                                                                                                                            |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 4  | Oil rate                                                                                                  | 960                                                                                                                        | STB/d                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 5  | Water rate                                                                                                | 640                                                                                                                        | STB/d                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 6  | Producing gas-oil ratio                                                                                   | 600                                                                                                                        | scf/STB                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 7  | Pump intake pressure                                                                                      | 1875                                                                                                                       | psi                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                      |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 8  | Intake temperature                                                                                        | 180                                                                                                                        | °F                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 9  | Oil gravity                                                                                               | 35                                                                                                                         | °API                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 10 | Gas specific gravity                                                                                      | 0.75                                                                                                                       | air = 1                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 11 | Separator (1 standard, 2 advanced, 3 tandem)                                                              | 1                                                                                                                          | —                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 12 | Free gas a standard pump takes, up to                                                                     | 0.1                                                                                                                        | %                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 13 | Free gas gas-handler stages take, up to                                                                   | 0.25                                                                                                                       | %                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 15 | Fluid at the Intake (Standing, McCain, Dranchuk–Abou-Kassem)                                              |                                                                                                                            |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 16 | Bubble point at the producing GOR                                                                         | =PO.PVT.Pb.ByStanding(GH_SGg,GH_API,GH_GOR,GH_T)                                                                           | psi                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                      |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 17 | Solution GOR at the intake, Rs                                                                            | =IF(GH_PIP>=GH_Pb,GH_GOR,MIN(GH_GOR,PO.PVT.Rs.ByStanding(GH_SGg,GH_API,GH_PIP,GH_T)))                                      | scf/STB                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 18 | Oil formation volume factor, Bo                                                                           | =PO.PVT.Bo.Sat.ByStanding(GH_SGg,GH_API,GH_Rs,GH_T)                                                                        | bbl/STB                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 19 | Water formation volume factor, Bw                                                                         | =PO.PVT.Bw.ByMcCain(GH_PIP,GH_T)                                                                                           | bbl/STB                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 20 | Gas deviation factor, z                                                                                   | =PO.PVT.Z.ByDAK(GH_PIP/PO.PVT.Ppc.ByStanding(GH_SGg),(PO.UnitConverter(GH_T,"degF","degR"))/PO.PVT.Tpc.ByStanding(GH_SGg)) | —                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 21 | Gas formation volume factor, Bg                                                                           | =PO.PVT.Bg.ByDefinition(GH_PIP,PO.UnitConverter(GH_T,"degF","degR"),GH_z)                                                  | ft³/scf                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 22 | Free Gas and the Gas-Handling Call                                                                        |                                                                                                                            |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 23 | Free gas at the intake, Qo·(GOR − Rs)·Bg                                                                  | =PO.UnitConverter(PO.ESP.Gas.Qg.Free(GH_Qo,GH_GOR,GH_Rs,GH_Bg),"ft3","bbl")                                                | rb/d                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 24 | Liquid at the intake, Qo·Bo + Qw·Bw                                                                       | =PO.ESP.Gas.Ql.Total(GH_Qo,GH_Qw,GH_Bo,GH_Bw)                                                                              | rb/d                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 25 | Free gas at the intake, share of the volume                                                               | =PO.ESP.Gas.Void(GH_Qg,GH_Ql)                                                                                              | %                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 26 | The same from the field rates in one step                                                                 | =PO.ESP.Gas.Void.Full(GH_Qo,GH_Qw,GH_GOR,GH_Rs,GH_Bo,GH_Bw,GH_Bg)                                                          | %                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 27 | Turpin factor                                                                                             | =PO.ESP.Gas.Turpin.Factor(GH_PIP,GH_Pb)                                                                                    | —                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 28 | Recommendation at the intake                                                                              | =""&PO.ESP.Gas.Recommendation(GH_Void)                                                                                     |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 29 | Separator efficiency                                                                                      | =PO.ESP.Gas.Sep.Eff(GH_Ql,GH_Void,CHOOSE(GH_SepType,"standard","advanced","tandem"))                                       | %                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 30 | Free gas into the pump, after the separator                                                               | =PO.ESP.Gas.Void.PostSep(GH_Void,GH_SepEff)                                                                                | %                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 31 | Recommendation after the separator                                                                        | =""&PO.ESP.Gas.Recommendation(GH_VoidSep)                                                                                  |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 32 | Gas-handling check                                                                                        | =IF(GH_PIP>=GH_Pb,"PASS",IF(GH_VoidSep<GH_VoidStd,"PASS",IF(GH_VoidSep<GH_VoidAgh,"WARN","FAIL")))                         | =IF(GH_PIP>=GH_Pb,"the intake is above the "&TEXT(GH_Pb,"#,##0")&" psi bubble point, so no free gas reaches the pump",IF(GH_VoidSep<GH_VoidStd,""&TEXT(GH_Void,"0.0%")&" free gas at the intake, "&TEXT(GH_VoidSep,"0.0%")&" after the separator, under the "&TEXT(GH_VoidStd,"0%")&" a standard pump takes",IF(GH_VoidSep<GH_VoidAgh,""&TEXT(GH_VoidSep,"0.0%")&" free gas after the separator; add gas-handler (AGH) stages below the pump",""&TEXT(GH_VoidSep,"0.0%")&" free gas after the separator, past what gas-handler stages take; set the pump deeper or consider gas lift"))) |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 35 | Free Gas against Intake Pressure (nothing to edit)                                                        |                                                                                                                            |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 36 | Intake pressures from a tenth of the bubble point up to it, at the same rates: how deep the pump must go. |                                                                                                                            |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                          |                                                                                                                                                                                          |                                                                                    |                                                                                                                                                                           |
| 37 | Intake pressure (psi)                                                                                     | Rs (scf/STB)                                                                                                               | Bo (bbl/STB)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             | Bg (ft³/scf)                                                                                                                                                                             | Void at intake (%)                                                                 | After separator (%)                                                                                                                                                       |
| 38 | =GH_Pb*1/10                                                                                               | =MIN(GH_GOR,PO.PVT.Rs.ByStanding(GH_SGg,GH_API,A38,GH_T))                                                                  | =PO.PVT.Bo.Sat.ByStanding(GH_SGg,GH_API,B38,GH_T)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        | =PO.PVT.Bg.ByDefinition(A38,PO.UnitConverter(GH_T,"degF","degR"),PO.PVT.Z.ByDAK(A38/PO.PVT.Ppc.ByStanding(GH_SGg),(PO.UnitConverter(GH_T,"degF","degR"))/PO.PVT.Tpc.ByStanding(GH_SGg))) | =PO.ESP.Gas.Void.Full(GH_Qo,GH_Qw,GH_GOR,B38,C38,PO.PVT.Bw.ByMcCain(A38,GH_T),D38) | =PO.ESP.Gas.Void.PostSep(E38,PO.ESP.Gas.Sep.Eff(PO.ESP.Gas.Ql.Total(GH_Qo,GH_Qw,C38,PO.PVT.Bw.ByMcCain(A38,GH_T)),E38,CHOOSE(GH_SepType,"standard","advanced","tandem"))) |
| 39 | =GH_Pb*2/10                                                                                               | =MIN(GH_GOR,PO.PVT.Rs.ByStanding(GH_SGg,GH_API,A39,GH_T))                                                                  | =PO.PVT.Bo.Sat.ByStanding(GH_SGg,GH_API,B39,GH_T)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        | =PO.PVT.Bg.ByDefinition(A39,PO.UnitConverter(GH_T,"degF","degR"),PO.PVT.Z.ByDAK(A39/PO.PVT.Ppc.ByStanding(GH_SGg),(PO.UnitConverter(GH_T,"degF","degR"))/PO.PVT.Tpc.ByStanding(GH_SGg))) | =PO.ESP.Gas.Void.Full(GH_Qo,GH_Qw,GH_GOR,B39,C39,PO.PVT.Bw.ByMcCain(A39,GH_T),D39) | =PO.ESP.Gas.Void.PostSep(E39,PO.ESP.Gas.Sep.Eff(PO.ESP.Gas.Ql.Total(GH_Qo,GH_Qw,C39,PO.PVT.Bw.ByMcCain(A39,GH_T)),E39,CHOOSE(GH_SepType,"standard","advanced","tandem"))) |
| 40 | =GH_Pb*3/10                                                                                               | =MIN(GH_GOR,PO.PVT.Rs.ByStanding(GH_SGg,GH_API,A40,GH_T))                                                                  | =PO.PVT.Bo.Sat.ByStanding(GH_SGg,GH_API,B40,GH_T)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        | =PO.PVT.Bg.ByDefinition(A40,PO.UnitConverter(GH_T,"degF","degR"),PO.PVT.Z.ByDAK(A40/PO.PVT.Ppc.ByStanding(GH_SGg),(PO.UnitConverter(GH_T,"degF","degR"))/PO.PVT.Tpc.ByStanding(GH_SGg))) | =PO.ESP.Gas.Void.Full(GH_Qo,GH_Qw,GH_GOR,B40,C40,PO.PVT.Bw.ByMcCain(A40,GH_T),D40) | =PO.ESP.Gas.Void.PostSep(E40,PO.ESP.Gas.Sep.Eff(PO.ESP.Gas.Ql.Total(GH_Qo,GH_Qw,C40,PO.PVT.Bw.ByMcCain(A40,GH_T)),E40,CHOOSE(GH_SepType,"standard","advanced","tandem"))) |
| 41 | =GH_Pb*4/10                                                                                               | =MIN(GH_GOR,PO.PVT.Rs.ByStanding(GH_SGg,GH_API,A41,GH_T))                                                                  | =PO.PVT.Bo.Sat.ByStanding(GH_SGg,GH_API,B41,GH_T)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        | =PO.PVT.Bg.ByDefinition(A41,PO.UnitConverter(GH_T,"degF","degR"),PO.PVT.Z.ByDAK(A41/PO.PVT.Ppc.ByStanding(GH_SGg),(PO.UnitConverter(GH_T,"degF","degR"))/PO.PVT.Tpc.ByStanding(GH_SGg))) | =PO.ESP.Gas.Void.Full(GH_Qo,GH_Qw,GH_GOR,B41,C41,PO.PVT.Bw.ByMcCain(A41,GH_T),D41) | =PO.ESP.Gas.Void.PostSep(E41,PO.ESP.Gas.Sep.Eff(PO.ESP.Gas.Ql.Total(GH_Qo,GH_Qw,C41,PO.PVT.Bw.ByMcCain(A41,GH_T)),E41,CHOOSE(GH_SepType,"standard","advanced","tandem"))) |
| 42 | =GH_Pb*5/10                                                                                               | =MIN(GH_GOR,PO.PVT.Rs.ByStanding(GH_SGg,GH_API,A42,GH_T))                                                                  | =PO.PVT.Bo.Sat.ByStanding(GH_SGg,GH_API,B42,GH_T)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        | =PO.PVT.Bg.ByDefinition(A42,PO.UnitConverter(GH_T,"degF","degR"),PO.PVT.Z.ByDAK(A42/PO.PVT.Ppc.ByStanding(GH_SGg),(PO.UnitConverter(GH_T,"degF","degR"))/PO.PVT.Tpc.ByStanding(GH_SGg))) | =PO.ESP.Gas.Void.Full(GH_Qo,GH_Qw,GH_GOR,B42,C42,PO.PVT.Bw.ByMcCain(A42,GH_T),D42) | =PO.ESP.Gas.Void.PostSep(E42,PO.ESP.Gas.Sep.Eff(PO.ESP.Gas.Ql.Total(GH_Qo,GH_Qw,C42,PO.PVT.Bw.ByMcCain(A42,GH_T)),E42,CHOOSE(GH_SepType,"standard","advanced","tandem"))) |
| 43 | =GH_Pb*6/10                                                                                               | =MIN(GH_GOR,PO.PVT.Rs.ByStanding(GH_SGg,GH_API,A43,GH_T))                                                                  | =PO.PVT.Bo.Sat.ByStanding(GH_SGg,GH_API,B43,GH_T)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        | =PO.PVT.Bg.ByDefinition(A43,PO.UnitConverter(GH_T,"degF","degR"),PO.PVT.Z.ByDAK(A43/PO.PVT.Ppc.ByStanding(GH_SGg),(PO.UnitConverter(GH_T,"degF","degR"))/PO.PVT.Tpc.ByStanding(GH_SGg))) | =PO.ESP.Gas.Void.Full(GH_Qo,GH_Qw,GH_GOR,B43,C43,PO.PVT.Bw.ByMcCain(A43,GH_T),D43) | =PO.ESP.Gas.Void.PostSep(E43,PO.ESP.Gas.Sep.Eff(PO.ESP.Gas.Ql.Total(GH_Qo,GH_Qw,C43,PO.PVT.Bw.ByMcCain(A43,GH_T)),E43,CHOOSE(GH_SepType,"standard","advanced","tandem"))) |
| 44 | =GH_Pb*7/10                                                                                               | =MIN(GH_GOR,PO.PVT.Rs.ByStanding(GH_SGg,GH_API,A44,GH_T))                                                                  | =PO.PVT.Bo.Sat.ByStanding(GH_SGg,GH_API,B44,GH_T)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        | =PO.PVT.Bg.ByDefinition(A44,PO.UnitConverter(GH_T,"degF","degR"),PO.PVT.Z.ByDAK(A44/PO.PVT.Ppc.ByStanding(GH_SGg),(PO.UnitConverter(GH_T,"degF","degR"))/PO.PVT.Tpc.ByStanding(GH_SGg))) | =PO.ESP.Gas.Void.Full(GH_Qo,GH_Qw,GH_GOR,B44,C44,PO.PVT.Bw.ByMcCain(A44,GH_T),D44) | =PO.ESP.Gas.Void.PostSep(E44,PO.ESP.Gas.Sep.Eff(PO.ESP.Gas.Ql.Total(GH_Qo,GH_Qw,C44,PO.PVT.Bw.ByMcCain(A44,GH_T)),E44,CHOOSE(GH_SepType,"standard","advanced","tandem"))) |
| 45 | =GH_Pb*8/10                                                                                               | =MIN(GH_GOR,PO.PVT.Rs.ByStanding(GH_SGg,GH_API,A45,GH_T))                                                                  | =PO.PVT.Bo.Sat.ByStanding(GH_SGg,GH_API,B45,GH_T)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        | =PO.PVT.Bg.ByDefinition(A45,PO.UnitConverter(GH_T,"degF","degR"),PO.PVT.Z.ByDAK(A45/PO.PVT.Ppc.ByStanding(GH_SGg),(PO.UnitConverter(GH_T,"degF","degR"))/PO.PVT.Tpc.ByStanding(GH_SGg))) | =PO.ESP.Gas.Void.Full(GH_Qo,GH_Qw,GH_GOR,B45,C45,PO.PVT.Bw.ByMcCain(A45,GH_T),D45) | =PO.ESP.Gas.Void.PostSep(E45,PO.ESP.Gas.Sep.Eff(PO.ESP.Gas.Ql.Total(GH_Qo,GH_Qw,C45,PO.PVT.Bw.ByMcCain(A45,GH_T)),E45,CHOOSE(GH_SepType,"standard","advanced","tandem"))) |
| 46 | =GH_Pb*9/10                                                                                               | =MIN(GH_GOR,PO.PVT.Rs.ByStanding(GH_SGg,GH_API,A46,GH_T))                                                                  | =PO.PVT.Bo.Sat.ByStanding(GH_SGg,GH_API,B46,GH_T)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        | =PO.PVT.Bg.ByDefinition(A46,PO.UnitConverter(GH_T,"degF","degR"),PO.PVT.Z.ByDAK(A46/PO.PVT.Ppc.ByStanding(GH_SGg),(PO.UnitConverter(GH_T,"degF","degR"))/PO.PVT.Tpc.ByStanding(GH_SGg))) | =PO.ESP.Gas.Void.Full(GH_Qo,GH_Qw,GH_GOR,B46,C46,PO.PVT.Bw.ByMcCain(A46,GH_T),D46) | =PO.ESP.Gas.Void.PostSep(E46,PO.ESP.Gas.Sep.Eff(PO.ESP.Gas.Ql.Total(GH_Qo,GH_Qw,C46,PO.PVT.Bw.ByMcCain(A46,GH_T)),E46,CHOOSE(GH_SepType,"standard","advanced","tandem"))) |
| 47 | =GH_Pb*10/10                                                                                              | =MIN(GH_GOR,PO.PVT.Rs.ByStanding(GH_SGg,GH_API,A47,GH_T))                                                                  | =PO.PVT.Bo.Sat.ByStanding(GH_SGg,GH_API,B47,GH_T)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        | =PO.PVT.Bg.ByDefinition(A47,PO.UnitConverter(GH_T,"degF","degR"),PO.PVT.Z.ByDAK(A47/PO.PVT.Ppc.ByStanding(GH_SGg),(PO.UnitConverter(GH_T,"degF","degR"))/PO.PVT.Tpc.ByStanding(GH_SGg))) | =PO.ESP.Gas.Void.Full(GH_Qo,GH_Qw,GH_GOR,B47,C47,PO.PVT.Bw.ByMcCain(A47,GH_T),D47) | =PO.ESP.Gas.Void.PostSep(E47,PO.ESP.Gas.Sep.Eff(PO.ESP.Gas.Ql.Total(GH_Qo,GH_Qw,C47,PO.PVT.Bw.ByMcCain(A47,GH_T)),E47,CHOOSE(GH_SepType,"standard","advanced","tandem"))) |

## Names

| Name | RefersTo | Comment |
|------|----------|---------|
| GH_Qo | $B$4 | Oil rate, STB/d |
| GH_Qw | $B$5 | Water rate, STB/d |
| GH_GOR | $B$6 | Producing gas-oil ratio, scf/STB |
| GH_PIP | $B$7 | Pump intake pressure, psi |
| GH_T | $B$8 | Intake temperature, °F |
| GH_API | $B$9 | Oil gravity, °API |
| GH_SGg | $B$10 | Gas specific gravity, air = 1 |
| GH_SepType | $B$11 | Separator (1 standard, 2 advanced, 3 tandem) |
| GH_VoidStd | $B$12 | Free gas a standard pump takes, up to, % |
| GH_VoidAgh | $B$13 | Free gas gas-handler stages take, up to, % |
| GH_Inputs | $B$4:$B$13 | Rates and GOR, the intake pressure and temperature, the fluid gravities, the separator and the void limits |
| GH_Pb | $B$16 | Bubble point at the producing GOR, psi |
| GH_Rs | $B$17 | Solution GOR at the intake, Rs, scf/STB |
| GH_Bo | $B$18 | Oil formation volume factor, Bo, bbl/STB |
| GH_Bw | $B$19 | Water formation volume factor, Bw, bbl/STB |
| GH_z | $B$20 | Gas deviation factor, z |
| GH_Bg | $B$21 | Gas formation volume factor, Bg, ft³/scf |
| GH_Qg | $B$23 | Free gas at the intake, Qo·(GOR − Rs)·Bg, rb/d |
| GH_Ql | $B$24 | Liquid at the intake, Qo·Bo + Qw·Bw, rb/d |
| GH_Void | $B$25 | Free gas at the intake, share of the volume, % |
| GH_VoidFull | $B$26 | The same from the field rates in one step, % |
| GH_Turpin | $B$27 | Turpin factor |
| GH_Advice | $B$28 | Recommendation at the intake |
| GH_SepEff | $B$29 | Separator efficiency, % |
| GH_VoidSep | $B$30 | Free gas into the pump, after the separator, % |
| GH_AdviceSep | $B$31 | Recommendation after the separator |
| GH_Check | $B$32 | Gas-handling check verdict |
| GH_CheckNote | $C$32 | Gas-handling check comment |
| GH_Results | $B$16:$B$32 | The PVT at the intake, the free gas and liquid there, the void before and after the separator, and the check |
| GH_Curve | $A$38:$F$47 | Free Gas against Intake Pressure |

---

## Related Blueprints
- [ESP Sizing and Operating Point](/blueprint/po.esp.operating.point.md)
- [ESP Cable Sizing and Voltage Drop](/blueprint/po.esp.cable.analysis.md)
- [ESP on a Variable-Speed Drive](/blueprint/po.esp.vsd.frequency.md)
- [Separator Sizing by Souders-Brown and Retention Time](/blueprint/po.sf.separator.sizing.md)
- [Inverted ESP Sizing for a Downhole Water Sink](/blueprint/po.esp.dws.sizing.md)
- [Multiphase Flowline by Beggs and Brill](/blueprint/po.sf.multiphase.flowline.md)